Vascular access for hemodialysis and cardiovascular complications

D Santoro1, V Savica, G Bellinghieri

  • 1Unit of Nephrology and Dialysis, University of Messina, Messina, Italy. santisi@hotmail.com

Native arterio-venous fistula (AVF), is the first choice of the vascular access for hemodialysis treatment. In comparison with other vascular accesses such as prosthetic arterio-venous graft or permanent central venous catheter, AVF has shown a significant reduction in cardiovascular mortality. It needs, of course, an appropriate blood flow that provides a flow of 400-800 mL/min in the distal seat and a flow of 800-1500 ml/min in the proximal seat. As a consequence, the creation of AVF may be associated with changes in blood flow, pulmonary pressure and cardiac output. All these haemodynamic changes may not have any cardiac consequences, or they could lead to congestive heart disease particularly when the blood flow of AVF is greater than 2000 ml/min. For this reason, the patient's cardiac status should determine the choice of dialysis and the type of vascular access. Cardiac function monitoring is essential, particularly when dealing with patients at high risk for congestive heart disease and AVF in the proximal seat. Vascular access reduction surgery may be effective in some cases, otherwise a suitable alternative could be that of closing AVF. However, the likely side effects that can be generated by closing arterio-venous AVF such as a sudden increase of venous peripheral systemic should be taken into account.

Related Concept Videos

Hemodialysis I: Introduction01:25

Hemodialysis I: Introduction

Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
Hemodialysis III: Nursing Management01:25

Hemodialysis III: Nursing Management

The nursing management of a patient undergoing hemodialysis includes several critical steps, starting with a thorough assessment before the procedure.Before the Hemodialysis ProcedureFirst, record the patient's vital signs—blood pressure, heart rate, respiratory rate, and temperature—to establish a baseline. This baseline is essential for detecting conditions such as hypotension that could impact the patient's response to dialysis. Document the patient's pre-dialysis weight, as this measurement...
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications01:25

Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications

Peritoneal dialysis (PD) is a medical process that removes waste products and excess fluid from the body using the peritoneal membrane as a natural filter.Peritoneal Dialysis MethodsSeveral methods can be used for peritoneal dialysis, including Acute Intermittent Peritoneal Dialysis, Continuous Ambulatory Peritoneal Dialysis, and Automated Peritoneal Dialysis, also known as Continuous Cyclic Peritoneal Dialysis.Acute Intermittent Peritoneal Dialysis (AIPD) is used for patients with uremic...
Dialysis01:27

Dialysis

Renal failure occurs when the kidneys lose their ability to filter waste products from the blood effectively. It can be classified into two types: acute renal failure (ARF) and chronic renal failure (CRF).
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Dialysis01:15

Dialysis

Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...