Computer-aided polyp detection on CT colonography: comparison of three systems in a high-risk human population
Hee Sun Park1, Se Hyung Kim, Jong Hyo Kim
1Department of Radiology, Seoul National University Hospital, 101 Daehangno, Jongno-gu, Seoul 110-744, Republic of Korea.
Purpose:
To compare the detection performances of two commercial and one academic computer-aided diagnosis (CAD) systems for polyp detection on CT colonography (CTC) in a high-risk human population and to assess their detection characteristics.
Materials And Methods:
This retrospective study had institutional review board approval, but informed consent was waived. Sixty-eight patients who were suspected of having colonic polyps and scheduled for colonoscopic polyp removal were included. After CTC was performed using a 64-row MDCT, two commercial (PEV, CAR) and one academic (Hessian matrix-based) CAD systems were applied to each CTC dataset. Colonoscopy using the segmental unblinded technique was performed as a standard of reference. Per-polyp and per-patient sensitivities were calculated and compared for each CAD system. The mean number of false-positives (FPs) and false-negatives (FNs) was computed and the causes of all FPs and FNs were analyzed.
Results:
A total of 151 polyps in 61 patients were detected (77 polyps <6mm, 48 6-9.9 mm, 26>or=10mm). Per-polyp sensitivity for PEV, CAR, and Hessian matrix-based CAD were: 71.6%, 78.4%, and 83.8% for polyps >or=6mm, and 88.5%, 96.2%, and 96.2% for polyps >or=10mm. Per-patient sensitivity for polyps >or=6mm was 80.4%, 89.1%, and 93.5%, and 87%, 95.7%, and 95.7% for polyps >or=10mm, respectively. Per-polyp and per-patient sensitivities were not significantly different among the three CAD systems regardless of size threshold. Mean number of FPs was 6.9 for PEV, 7.3 for CAR, and 14 for Hessian matrix-based CAD. The most common cause of FPs were feces, followed by extracolonic findings, prominent folds and ileocecal valve, and rectal tube. The distribution of the causes of FPs was significantly different among the three systems.
Conclusion:
Sensitivity of the three CAD systems for polyp detection was comparable regardless of the polyp size threshold; however, the number of FPs was higher in the Hessian matrix-based CAD. In addition, the distribution of the causes of FPs was significantly different among the three systems.
More Related Videos
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
06:28E-Patient Counseling Trial (E-PACO): Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT