Home sphygmomanometers: what should a nephrologist know?
1Department of Nephrology, Ondokuz Mayis University School of Medicine, Samsun - Turkey. tekinakpolat@yahoo.com
Abstract:
Inaccuracy of home sphygmomanometers is a common, neglected and often ignored problem. The aims of this review are to emphasize the advantages of self-measurement of blood pressure (BP) at home, to summarize basic features of automated home BP measurement devices, to point out the distinction between validation, calibration and accuracy of home sphygmomanometers and to discuss some practical points for the improvement of BP control in chronic kidney disease (CKD) patients for nephrologists. Four features of automated sphygmomanometers need to be emphasized: measurement site, cuff-size, validation status and accuracy. The validation protocols do not guarantee the accuracy of a particular device for an individual patient. Special patient groups such as those with early stages of CKD or diabetic nephropathy or patients having extraosseous/vascular calcifications may require specific validation tests. Active guidance by nephrologists in all steps of self-measurement of BP at home will improve the control of BP and will increase the quality of patient care in CKD. Health care providers must urgently reimburse the cost of accurate home sphygmomanometers for patients with CKD in countries where CKD is considered a major public health problem.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Assessing Blood pressure in the Leg
Preparation:
Measurement of Blood Pressure