Resolving Water, Proteins, and Lipids from In Vivo Confocal Raman Spectra of Stratum Corneum through a Chemometric Approach
Published on: September 26, 2019
Quantification of crocetin esters in saffron (Crocus sativus L.) using Raman spectroscopy and chemometrics
Eirini G Anastasaki1, Charalabos D Kanakis, Christos Pappas
1Laboratory of Chemistry, Department of Science, Agricultural University of Athens, 75 Iera Odos, 11855 Athens, Greece.
Abstract:
The feasibility of Raman spectroscopy for predicting the content of crocetin esters (crocins), and coloring strength was assessed. 114 samples from Greece, Iran, Italy and Spain were divided into two sets: a calibration set with 49 samples and a validation one with 65 samples. Calibration models for crocetin esters (r 0.97, RMSEC 0.92, RMSEP 0.97, RPD 3.46) and coloring strength (r 0.95, RMSEC 12.2, RMSEP 11.3, RPD 2.59) were built in the spectral region 1700-955 cm(-1) using partial least-squares (PLS) regression. The calibration models were validated using cross-validation, leaving one sample out (r 0.97, RMSECV 1.09 for crocetin esters and r 0.93, RMSECV 14.5 for coloring strength). The crocetin esters content as determined by liquid chromatography fluctuated between 18.8 and 31.7 mg/100 g saffron. The corresponding values, as calculated using the Raman method, fluctuated between 19.2 and 32.0 mg/100 g saffron. The coloring strength determined by the reference method ranged from 177.0 to 296.7 units, while with the Raman method the values were between 186.8 and 297.6 units. The results, as compared to the reference methods (liquid chromatography and UV-vis spectrophotometry), show that the proposed methodology gives data with acceptable accuracy. The proposed models can be used as a tool for rapid screening of quality in saffron samples.
More Related Videos
09:50Enhanced Photoluminescence of Curcuma longa Extracts via Chitosan-Mediated Energy Transfer for Textile Authentication Applications
Published on: December 22, 2023
07:29HPLC Coupled with Chemical Fingerprinting for Multi-Pattern Recognition for Identifying the Authenticity of Clematidis Armandii Caulis
Published on: November 11, 2022
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Spectroscopy of Carboxylic Acid Derivatives
In the...
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...