Quantitative analysis of mixed hydrofluoric and nitric acids using Raman spectroscopy with partial least squares
Gumin Kang1, Kwangchil Lee, Haesung Park
1School of Mechanical Engineering, Yonsei University, Seoul, Republic of Korea.
Abstract:
Mixed hydrofluoric and nitric acids are widely used as a good etchant for the pickling process of stainless steels. The cost reduction and the procedure optimization in the manufacturing process can be facilitated by optically detecting the concentration of the mixed acids. In this work, we developed a novel method which allows us to obtain the concentrations of hydrofluoric acid (HF) and nitric acid (HNO(3)) mixture samples with high accuracy. The experiments were carried out for the mixed acids which consist of the HF (0.5-3wt%) and the HNO(3) (2-12wt%) at room temperature. Fourier Transform Raman spectroscopy has been utilized to measure the concentration of the mixed acids HF and HNO(3), because the mixture sample has several strong Raman bands caused by the vibrational mode of each acid in this spectrum. The calibration of spectral data has been performed using the partial least squares regression method which is ideal for local range data treatment. Several figures of merit (FOM) were calculated using the concept of net analyte signal (NAS) to evaluate performance of our methodology.
More Related Videos
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Mixtures of Acids
A Mixture of a Strong Acid and a Weak Acid
In a mixture of a strong acid and a weak acid, the strong acid dissociates completely and becomes a source of almost all the hydronium ions...
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
Spectroscopy of Carboxylic Acid Derivatives
In the...
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...