Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Jun 13, 2026

Application of Optical Coherence Tomography to a Mouse Model of Retinopathy
08:22

Application of Optical Coherence Tomography to a Mouse Model of Retinopathy

Published on: January 12, 2022

Optical thickness monitoring sensitivity improvement using graphical methods.

R R Willey

    Applied Optics
    |May 11, 2010
    PubMed
    Summary

    Semidirect level monitoring offers error compensation for optical coatings. This method, using circle diagrams and optimum level trigger points, improves film thickness accuracy and reduces errors during optical monitoring.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Estimating the number of layers required and other properties of blocker and dichroic optical thin films.

    Applied optics·2010
    Same author

    Predicting achievable design performance of broadband antireflection coatings.

    Applied optics·2010
    Same author

    Resolution of two problems in the Fourier analysis of thin films.

    Applied optics·2010
    Same author

    Fourier-transform method for the design of wideband antireflection coatings.

    Applied optics·2010
    Same author

    Antireflection coating for high index cemented doublets.

    Applied optics·2010
    Same author

    Graphic description of equivalent index approximations and limitations.

    Applied optics·2010

    Area of Science:

    • Optical Engineering
    • Materials Science

    Background:

    • Optical coatings require precise thickness control for performance.
    • Traditional monitoring methods can introduce significant errors.
    • Semidirect level monitoring offers potential for enhanced accuracy.

    Purpose of the Study:

    • To review principles of optical level monitoring using circle diagrams.
    • To design a level monitoring scheme for optical coatings.
    • To evaluate the effectiveness of optimum level trigger point monitoring.

    Main Methods:

    • Analysis of optical monitoring principles via circle diagrams.
    • Design of a level monitoring scheme for optical coatings.
    • Investigation of film thickness sensitivities for different monitoring strategies.
    • Application and description of optimum level trigger point monitoring.

    Main Results:

    • Different optical monitoring strategies exhibit varying film thickness sensitivities.
    • Optimum level trigger point monitoring enhances sensitivity to reflectance changes.
    • This method is expected to minimize thickness errors in optically monitored films.

    Conclusions:

    • Semidirect level monitoring, particularly with optimum level trigger points, provides error compensation benefits.
    • The described method offers improved precision for optical coating fabrication.
    • Circle diagram analysis is crucial for designing effective monitoring schemes.

    More Related Videos

    In Vivo Imaging of Cx3cr1gfp/gfp Reporter Mice with Spectral-domain Optical Coherence Tomography and Scanning Laser Ophthalmoscopy
    06:19

    In Vivo Imaging of Cx3cr1gfp/gfp Reporter Mice with Spectral-domain Optical Coherence Tomography and Scanning Laser Ophthalmoscopy

    Published on: November 11, 2017

    Related Experiment Videos

    Last Updated: Jun 13, 2026

    Application of Optical Coherence Tomography to a Mouse Model of Retinopathy
    08:22

    Application of Optical Coherence Tomography to a Mouse Model of Retinopathy

    Published on: January 12, 2022

    In Vivo Imaging of Cx3cr1gfp/gfp Reporter Mice with Spectral-domain Optical Coherence Tomography and Scanning Laser Ophthalmoscopy
    06:19

    In Vivo Imaging of Cx3cr1gfp/gfp Reporter Mice with Spectral-domain Optical Coherence Tomography and Scanning Laser Ophthalmoscopy

    Published on: November 11, 2017