Related Experiment Video
Updated: Jun 13, 2026

Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees
Published on: July 15, 2009
Parameters for successful implant integration revisited part I: immediate loading considered in light of the original
Oded Bahat1, Richard M Sullivan
1odedbahat@aol.com
Purpose:
With the increasing popularity and publication of loading implants at the time of placement, including at time of dental extraction and simultaneous with reconstructive procedures, the objective was to evaluate known variables identified for a traditional unloaded healing period and determine the applicability of these variables to immediate loading.
Materials:
A total of 124 published reports available as of January 2008 that contained information about loading from the time of surgery up to 3 months postsurgically were examined in light of published variables affecting osseointegration based on a 2 stage surgical approach.
Methods:
The articles were examined to differentiate between immediate loading (within the initial 48 hours) and early/delayed loading of implants. Success or survival criteria were noted, and where reasons for failure were available, categorized according to six variables considered as determinants for maintaining a long-term bone-to-implant contact.
Results:
Approximately 60 of the 124 reports described immediately loading implants within 48 with single-tooth, partial, and full-arch restorations, as well as implant overdentures. The implant success or survival rates ranged from 70.8% to 100%. Most studies considered implant survival to be the only criterion for success.
Conclusions:
Of six parameters identified in 1981 as influencing osseointegration, two parameters (the status of the bone/implant site and implant loading conditions) appear to have diagnostic implications, whereas three (implant design, surgical technique, and implant finish) may affect immediate loading positively or adversely.