Powerplex® ES versus Powerplex® S5--casework testing of the new screening kit
Micaela Poetsch1, Thomas Kamphausen, Thomas Bajanowski
1Institute of Forensic Medicine, University Hospital Essen, Essen, Germany. micaela.poetsch@uk-essen.de
Forensic Science International. Genetics
|May 12, 2010
Summary
The Powerplex® S5 Mini STR-System reliably analyzes degraded DNA in forensic casework, outperforming the Powerplex® ES kit in 64% of cases, especially for challenging samples like formalin-fixed tissues and telogen hair.
Area of Science:
- Forensic Science
- Molecular Biology
- Genetics
Background:
- Forensic DNA analysis often encounters degraded DNA from casework samples.
- Existing kits may yield poor results with highly degraded or inhibitor-containing DNA.
Purpose of the Study:
- To evaluate the Powerplex® S5 Mini STR-System as a screening tool for difficult forensic casework samples.
- To compare its performance against the Powerplex® ES kit for degraded DNA analysis.
Main Methods:
- Amplification of highly degraded DNA from casework samples and artificially degraded DNA.
- Inclusion of DNA samples with PCR inhibitors.
- Comparison of results with the Powerplex® ES kit.
Main Results:
- The Powerplex® S5 kit demonstrated reliability in analyzing degraded DNA, yielding better results than the Powerplex® ES kit in 64% of analyzed swabs.
- Allelic drop-in was observed in highly degraded DNA amplification.
- The system proved effective for formalin-fixed tissues, putrefied samples, and telogen hair.
Conclusions:
- The Powerplex® S5 Mini STR-System is a valuable screening tool for challenging forensic casework samples with degraded DNA.
- It offers improved performance over the Powerplex® ES kit for certain sample types.
- No direct correlation was found between positive Powerplex® S5 results and Powerplex® ES kit amplification success.