Related Experiment Video
Updated: May 7, 2026

Evaluation of Respiratory System Mechanics in Mice using the Forced Oscillation Technique
Published on: May 15, 2013
Exhaled nitric oxide, lung function, and exacerbations in wheezy infants and toddlers
Jason S Debley1, David C Stamey, Elizabeth S Cochrane
1Department of Pediatrics, Division of Pulmonary Medicine, Seattle Children's Hospital, University of Washington, Seattle, WA, USA. jason.debley@seattlechildrens.org
Background:
There are limited data assessing the relationship between fraction of exhaled nitric oxide and lung function or exacerbations in infants with recurrent wheezing.
Objectives:
In a longitudinal pilot study of children less than 2 years old, we assessed whether baseline fraction of exhaled nitric oxide was associated with lung function, bronchodilator responsiveness, changes in lung function, or subsequent exacerbations of wheezing.
Methods:
Forced expiratory flows and volumes using the raised-volume rapid thoracic compression method were measured in 44 infants and toddlers (mean age, 15.7 months) with recurrent wheezing. Single-breath exhaled nitric oxide (SB-eNO) was measured at 50 mL/s. Lung function was again measured 6 months after enrollment.
Results:
At enrollment, forced expiratory volume in 0.5 seconds (FEV(0.5)), forced expiratory flow at 25% to 75% of expiration (FEF(25-75)), and forced expiratory flow at 75% of expiration (FEF(75)) z scores for the cohort were significantly less than zero. There was no correlation between enrollment SB-eNO levels and enrollment lung function measures. SB-eNO levels were higher in infants with bronchodilator responsiveness (46.1 vs 23.6 ppb, P < .001) and was associated with a decrease in FEV(0.5) (r = -0.54, P = .001), FEF(25-75) (r = -0.6, P < .001), and FEF(75) (r = -0.55, P = .001) over 6 months. A 10-ppb increase in SB-eNO level was associated with a 0.4-point z score decrease in FEV(0.5), a 0.4-point z score decrease in FEF(25-75), and a 0.42-point z score decrease in FEF(75). SB-eNO level was superior to lung function and bronchodilator responsiveness in predicting subsequent wheezing treated with systemic steroids.
Conclusions:
SB-eNO level might predict changes in lung function and risk of future wheezing and holds promise as a biomarker to predict asthma in wheezy infants and toddlers.
More Related Videos
05:46A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
08:44Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
Published on: February 2, 2024
Related Concept Videos
Breathing
Pulmonary Cycle: Exhalation
Asthma-I: Introduction
Asthma I: Introduction
Asthma III: Clinical Manifestations
Chronic Obstructive Pulmonary Disease III: Chronic Bronchitis Features