Objectives:
To evaluate the role of video-urodynamic examination prior to renal transplantation.
Methods:
Sixty-four kidney transplant recipients were included into the study. All patients underwent video-urodynamic examination and separate uroflowmetry. Results were evaluated based on daily mean amount of urine, duration of chronic renal failure and presence of diabetes mellitus.
Results:
Thirty-five (54.6%) patients showed video-urodynamic abnormalities. The mean detrusor capacity was 234 ml, the mean detrusor compliance was 17.5 cm H(2)O/ml, the mean maximum detrusor pressure was 61.9 cm H(2)O and the mean Q (max) was 13.8 ml/s in all patients. Vesicoureteral reflux was detected in 15 (23%) patients. The mean detrusor compliance and detrusor capacity significantly decreased as the daily amount of urine decreased and as the duration of chronic renal failure increased. Also, there was no significant relation between presence of diabetes mellitus and detrusor capacity and detrusor compliance.
Conclusion:
Video-urodynamic studies before renal transplantation provide earlier diagnosis of lower tract abnormalities, which are likely to cause graft dysfunction.