Portable instrument for the volume measurement of high-frequency percussive ventilators - biomed 2010
Related Experiment Video
Updated: Jun 13, 2026

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Fabio Riscica1, Umberto Lucangelo, Agostino Accardo
1University of Trieste, Trieste, Italy.
Abstract:
In recent years, the usefulness of High Frequency Percussive Ventilation (HFPV) has been clinically valued as a suitable alternative to conventional mechanical ventilation especially in particularly conditions (for example in pulmonary resection [1]). However, sophisticated and expensive equipments are required for measuring the respiratory parameters during HFPV, because of the fast flow variation requiring output conditioning of the standard transducers with a complicated and expensive apparatus. In this paper, a compact, portable and inexpensive innovative system for the volume measurement during HFPV is described. The system uses pressure transducers of new generation with high sensitivity (up to 0.25 inches of water) and reduced response time (0.5 milliseconds). It acquires the flow with a sampling rate of 2 KHz, computes the volume every 64 samples by numerical integration and sends the values to a visualization device (Hewlett Packard HP50g) that updates the numerical value and the volume plot every 32 milliseconds. In order to verify the device reliability, a test system was produced. The output of a Percussionaire (VDR-4) was connected to a lung-simulator and the pressure and flow measures were carried out both by means of a laboratory measurement system of respiratory parameters (VT+) and of our portable device. The results show that the sampling frequency of the VT+ (50 Hz) is insufficient in the case of percussive ventilation, producing unacceptable errors (about 20%) in the volume evaluation; on the contrary, the sampling frequency of our system (2 KHz) allows to gain correct results. In conclusion, the suitable sampling frequency together with the system portability allow our device to realize a precise monitoring of respiratory parameters, during HFPV, of patients in surgery room or in intensive care unit.
Related Concept Videos
Physical Assessment of the Respiratory Tract III: Percussion
Percussion in Respiratory Assessment
Percussion evaluates underlying tissue composition with audible and tactile vibrations,...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...