Related Experiment Video
Updated: Jun 13, 2026

Application of a New Mesh Fixation Method in Laparoscopic Incisional Hernia Repair
Published on: December 23, 2022
Single incision laparoscopic totally extraperitoneal inguinal hernia repair
1Department of General Surgery, Huashan Hospital Hernia Center, Shanghai Medical College, Fudan University, Shanghai, China.
Aims:
Various single incision laparoscopic surgeries (SILS) and natural orifice transluminal endoscopic surgeries (NOTES) have been reported recently. Herein we performed SILS for totally extraperitoneal inguinal hernia repair (TEP) on three cases.
Cases:
Three males of 72, 49, and 73 years old with the diagnoses of bilateral primary inguinal hernia underwent single incision TEP. The operative steps of single incision TEP are very similar to those of a traditional laparoscopic TEP. The difference between them is a 2 cm infraumbilical incision for the placement of three (5 mm) trocars in single incision TEP. We preferred to use a 30° 5 mm laparoscope with some routine laparoscopic instruments during the surgical procedure. All the hernia defects were repaired with VyproII of 15 × 10 cm (Ethicon, NJ, USA). The operations took 32, 26, and 65 min, respectively, with no obvious inconvenience.
Results:
All three patients were discharged on the second postoperative day uneventfully. The postoperative follow-up showed no recurrence in the three patients up to now.
Conclusion: