Related Experiment Video
Updated: Jun 13, 2026

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Evaluation of ventricular synchrony with equilibrium radionuclide angiography: assessment of variability and accuracy
Enrique Vallejo1, Luis Jiménez, Gerardo Rodríguez
1Instituto Nacional de Cardiologia Ignacio Chavez, Cardiologia Nuclear, Tlalpan, Mexico, D.F., Mexico. vallejo.enrique@gmail.com
Background And Aims:
Equilibrium radionuclide angiography (ERNA) has become an established method for assessing cardiac function. However, limited data are available to evaluate ventricular synchrony with ERNA. The aim of this study was to assess the variability and accuracy of ERNA to evaluate ventricular synchrony by means of phase images in healthy individuals and to compare them with a group of subjects with left bundle-branch block (interventricular dyssynchrony, LBBB) and with a group of patients with nonischemic, dilated cardiomyopathy (DCM) (inter- and intraventricular dyssynchrony).
Methods:
The population was divided into groups as follows: group 1 included 22 healthy subjects, group 2 included 11 patients with LBBB and normal left ventricular ejection fraction (LVEF), and group 3 included 14 DCM patients with LVEF <35% and LBBB. Interventricular synchrony was measured as the difference between LV mean phase angle (mPA) and RV mPA (LV-RV mPA). Intraventricular synchrony for each ventricle was measured as the standard deviation (SD) of the RV mPA and LA mPA blood pools.
Results:
Intra- and interobserver correlation coefficients were high for both inter- and intraventricular synchrony parameters. Area under the curve (AUC) was 0.98 for LV-RV mPA (p <0.001; 95% CI: 0.947-1.0). A cutoff value of 10 degrees yielded 96% sensitivity and 99% specificity to identify interventricular dyssynchrony. AUC was high for SD RV mPA and SD LV mPA (AUC = 1.0, p <0.001; 95% CI: 1.0-1.0 and AUC = 0.99, p <0.001; 95% CI: 0.979-1.0). A cutoff value of 22 degrees for SD LV mPA yielded 100% sensitivity and 100% specificity to identify LV intraventricular dyssynchrony. A cutoff value of 20 degrees for SD RV mPA yielded 100% sensitivity and 99% specificity to identify RV intraventricular dyssynchrony.
Conclusions:
ERNA is an accurate and highly reproducible technique for evaluation of ventricular function and synchrony.
Related Concept Videos
Dysrhythmias V: Evaluating Dysrhythmias
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
