Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
Multi-group approximation, scattering and calibration coefficients, uncertainty estimates and detection limits of a
1Laboratoire de Physique Nucléaire, Faculté des Sciences, Université de Yaoundé I, Cameroon. aowono1@yahoo.fr
Abstract:
This paper describes a quantitative radioactivity analysis method especially suitable for environmental samples with low-level activity. The method, consisting of a multi-group approximation based on total absorption and Compton spectra of gamma rays, is coherently formalized and a computer algorithm thereof designed to analyze low-level activity NaI(Tl) gamma ray spectra of environmental samples. Milk powder from 1988 was used as the example case. Included is a special analysis on the uncertainty estimation. Gamma sensitiveness is defined and numerically evaluated. The results reproduced the calibration data well, attesting to the reliability of the method. The special analysis shows that the uncertainty of the assessed activity is tied to that of the calibration activity data. More than 77% of measured 1461-keV photons of (40)K were counted in the range of clearly lower energies. Pile-up of single line photons ((137)Cs) looks negligible compared to that of a two-line cascade ((134)Cs). The detection limit varies with radionuclide and spectrum region and is related to the gamma sensitiveness of the detection system. The best detection limit always lies in a spectrum region holding a line of the radionuclide and the highest sensitiveness. The most radioactive milk powder sample showed a activity concentration of 21+/-1 Bq g(-1)for (137)Cs, 323+/-13 Bq g(-1) for (40)K and no (134)Cs.
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Emission Spectroscopy: Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Interference
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...