Point-Of-Care Ultrasound Screening for Proximal Lower Extremity Deep Venous Thrombosis
Published on: February 10, 2023
Discrimination of types of venous emboli using Doppler ultrasound
Akito Mitsuoka1, Yoshinori Inoue, Hiroko Kume
1Department of Vascular and Applied Surgery, Tokyo Medical and Dental University, Graduate School of Medicine, Tokyo, Japan. mitsuo-ham@umin.ac.jp
Background:
Many studies have identified features of the emboli traveling in the arterial system by Doppler ultrasound, and estimated their composition and size for anticipation of cerebral infarct. Another concern is features of the emboli in the venous system for anticipation of pulmonary embolism (PE). The objective is to prove that the emboli in the venous system can be discriminated by Doppler ultrasound in animal study and to assess whether PE can be predicted by using this technique in clinical case.
Methods:
Animal study--lard oil, thrombus, or bone marrow was injected to the femoral veins in pigs. High intensity transient signals were transhepatically identified at the inferior vena cava using Doppler ultrasound. Intensity volume (dB) and frequency shift (Hz) of each signal were obtained. The cutoff values at which thrombi, fat emboli, and marrow emboli could be discriminated were calculated by receiver-operating characteristic curves analysis. Human study--Subjects were 47 patients who underwent total knee arthroplasty. On postoperative day 0 and 1, High intensity transient signals were identified at the affected common femoral vein using Doppler ultrasound. Contrast computed tomography was done, and the patients were divided into two groups according to the presence of PE. The two groups were distinguished by intensity volume (dB) and frequency shift (Hz) of each signal and calculated the sensitivity and specificity. The statistics analysis was done as in animal study.
Results:
Animal study--Thrombus and bone marrow could be discriminated from lard oil well at frequency shift of 208 Hz and 196 Hz (with sensitivity of 86.9, 85.7%, and specificity of 82.3%, 91.8%, respectively). Human study--The sensitivity and specificity were 76.7 and 75.0% to discriminate patients with and without PE at frequency shift of 208 Hz.
Conclusions:
Our animal study results indicated that emboli could be identified and discriminated in the venous system. Clinical study informed that the frequency shift (208 Hz) of the Doppler signal was the best parameter to discriminate PE with and without PE in patients with total knee arthroplasty.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Venous Thrombosis III: Interprofessional Care
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation