Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
Torn atrial septum during transcatheter closure of atrial septal defect visualized by real-time three-dimensional
Yasufumi Kijima1, Manabu Taniguchi, Teiji Akagi
1Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan.
Abstract:
Transcatheter closure of atrial septal defects (ASDs) has become an accepted and reliable procedure. Although various complications have been recognized, tear of the atrial septal rim is a rare complication. We report a case of atrial septal rim tear that was diagnosed during the procedure by real-time three-dimensional transesophageal echocardiography (TEE). The device was successfully implanted 3 months after the initial intervention. RT3D TEE is more useful for displaying the entire shape of the defect and its spatial relationship (RT3D) with its neighboring structures compared with conventional two-dimensional echocardiography. By using both two-dimensional and RT3D TEE images, especially in cases with complicated ASD morphology, both the echocardiologist and interventionalist gain valuable information on the morphology of the ASD before and during the procedure.
More Related Videos
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015