Objectives:
To determine the feasibility of a dynamic CT angiography-protocol in regard to simultaneous assessment of morphology and function.
Method And Materials:
Fourteen patients with renal graft dysfunction received a dynamic computed tomography angiography (CTA) using a 128-slice CT-scanner with continuous bi-directional table movement, allowing to cover a scan range of 18 cm within 1.75 seconds. Twelve scans of the entire kidney were acquired every 3.5 seconds with the aim to simultaneously obtain CTA and renal function data. The glomerular filtration rate (GFR) was calculated by a modified Patlak method and compared with creatinine-based formulas (MDRD 4 and endogenous creatinine clearance), that served as reference standard.
Results:
GFR obtained from dynamic CTA correlates well with the GFR derived by creatinine-based formulas with a correlation coefficient of r = 0.8986; P < 0.0001. The average absolute deviation was 8.1 mL/min. The mean amount of contrast medium required was 35 mL. The average effective dose was 13.8 mSv.
Conclusion:
Dynamic CTA offers the possibility to determine the GFR and thus facilitates simultaneous assessment of morphology and function. Additionally, our dynamic CTA-protocol helps to significantly reduce the amount of contrast medium, which is beneficial for patients with impaired renal function.
Related Concept Videos
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Imaging Studies VII: Vascular Imaging
Glomerular Filtration Rate and its Regulation
GFR regulation involves two primary intrinsic controls: the myogenic and tubuloglomerular feedback mechanisms.
The myogenic...
Imaging Studies III: Computed Tomography
Renal Drug Excretion: Glomerular Filtration
Drugs gain access to the kidney via the renal artery, which progressively branches off into afferent arterioles.