Related Experiment Video
Updated: Jun 12, 2026

A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
[A pilot study of trans-esophageal aortic pulse oxygen saturation signals]
1Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu 610041, China.
Abstract:
It is the intent of this study to simulate the performance of trans-esophageal aortic blood oxygen saturation (SeO2) monitoring by using trans-esophageal echocardiography (TEE) probe to provide an evidence for proper positioning of placing SeO2 sensor. 25 selected cardiac surgical patients were involved. After anesthesia was induced and trachea was intubated, the multiplane TEE probe was inserted into the esophagus, and the depths from the fore-tooth to the location for detecting aorta were recorded when the distances between TEE probe and aorta anterior wall were shorter than 0.5 cm, 1 cm, and longer than 1 cm, respectively. The o'clock directions of TEE probe were also recorded. The multiplane TEE probe, with its one-use pediatric SpO2 sensor attached, was inserted, and its anterior structure was examined when trans-esophagus oximetry detected high quality SpO2 signals. The results showed the beginning position of detecting aortic SpO2 signal in esophagus was mid esophagus (24.8 +/- 4.4 cm from the fore-teeth), the moving range was 5-10 cm downward, the deepest depth of detecting descending aorta was 41.4 +/- 4.7 cm from the fore-tooth, and the direction was left-posterior. And photoplethymography (PPG) wave's form was changed when SpO2 probe's anterior structure was different.
More Related Videos
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...