Planning design of locally advanced pancreatic carcinoma using 4DCT and IMRT/IGRT technologies
Giulia Sangalli1, Paolo Passoni, Giovanni M Cattaneo
1Medical Physics Department, San Raffaele Scientific Institute, Milan, Italy.
Background And Purpose:
to study the impact of the 4DCT imaging technique on radiotherapy planning for pancreatic carcinoma. To evaluate the possibility of IMRT/IGRT to increase the dose to PTV subvolume.
Material And Methods:
contrast-enhanced 4DCT scans of 15 patients (PTs) with unresectable pancreatic cancer were acquired. A 4DCT based PTV (4D-PTV) was created by the convolution of contours and then expanded for geometric uncertainties; a standard PTV (STD-PTV) was derived from a single CTV plus conventional margins. Two 3D conformal treatment (3DCRT) plans and one Helical Tomotherapy (HT) plan were generated with a prescription of 60 Gy. Regarding the 3DCRT plans, the 4D-PTV was considered as the target volume for one, and the STD-PTV for the other; the HT plans were performed only for 4D-PTV. Twelve of 15 PTs were admitted to a Phase I hypofractionated study (15 fractions). The prescribed dose was 44.25 Gy to the 4D-PTV and the PTV subvolume around vascular involvement was boosted from 50 to 55 Gy; before treatment, daily patient position was corrected using MVCT.
Results:
4D-PTVs were smaller than STD-PTVs with a volume reduction equal to 37%. 3DCRT plans on 4D-PTV showed a significant sparing of most OARs, the use of IMRT allowed a further significant dose reduction. In the Phase I study the PTV subvolume received up to 55 Gy with modest increase in dose to OARs.
Conclusions:
the 4DCT procedure decreases the overlap between PTV and OARs. HT technique, compared with 3DCRT, allows efficient dose sparing in particular for the duodenum. The IMRT/IGRT approach allows a safe dose escalation to PTV subvolume.