Related Experiment Video
Updated: Jun 12, 2026

Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
Horizontal alveolar distraction of the mandibular canine regions for implant placement
Emel Bulut1, Mehtap Muglali, Nukhet Celebi
1Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Ondokuz Mayis University, Samsun, Turkey.
Abstract:
Horizontal alveolar augmentation by distraction osteogenesis is an alternative method for reconstructing atrophic alveolar bone. A 65-year-old woman with atrophy of the alveolar rim in the anterior lower jaw, which had inadequate width for implant placement, was presented. Under general anesthesia, vertical and horizontal osteotomies of the buccolabial cortical bone were performed in the canine regions bilaterally. Modified horizontal distraction devices were stabilized to the mandible. Distraction proceeded from the seventh postoperative day at a rate of 0.450 mm twice a day for 6 days. After 3 months, distraction osteogenesis occurred and increased the alveolar width from 2 to 7 mm. Two implants were placed in the distracted areas. Marginal bone resorbtion around the implants was not observed 12 months after implant placement.