Related Experiment Video
Updated: Jun 12, 2026

Less-Invasive Technique for Non-stabilized Mandibular Fracture in Mouse Models
Published on: September 27, 2024
Reduction of mandible fractures with direct bonding technique and orthodontic appliances: two case reports
Chih-yu Chen1, Li-ren Chang, Wen-hui Chen
1Section of Orthodontics, Department of Dentistry, E-da Hospital, Kaohsiung County, Taiwan.
Abstract:
Intermaxillary fixation (IMF) with the arch bars or looped wires has been widely used to treat mandible fractures. However, manipulation of these appliances takes time and the medical staff is endangered by wire stabbing injuries. A modified method, the direct bonding technique combined with orthodontic appliances, simplifies the IMF concept to overcome these problems. It is faster, safer and easier to apply while the response of patients, with respect to treatment results, ease of the living and oral hygiene is more favorable. This report presents two cases of mandible fractures treated according to this protocol which resulted in good outcomes as expected.