Related Experiment Video
Updated: Jun 12, 2026

Dried Blood and Serum Spots As A Useful Tool for Sample Storage to Evaluate Cancer Biomarkers
Published on: June 11, 2018
Pleural fluid: Are temperature and storage time critical preanalytical error factors in biochemical analyses?
Leila Antonangelo1, Francisco S Vargas, Milena M P Acencio
1Pleura Laboratory - Pulmonary Division, Heart Institute (InCor), University of Sao Paulo Medical School, Brazil. l.antonangelo@uol.com.br
Background:
Biochemical analysis of fluid is the primary laboratory approach in pleural effusion diagnosis. Standardization of the steps between collection and laboratorial analyses are fundamental to maintain the quality of the results. We evaluated the influence of temperature and storage time on sample stability.
Methods:
Pleural fluid from 30 patients was submitted to analyses of proteins, albumin, lactic dehydrogenase (LDH), cholesterol, triglycerides, and glucose. Aliquots were stored at 21 degrees , 4 degrees , and-20 degrees C, and concentrations were determined after 1, 2, 3, 4, 7, and 14 days. LDH isoenzymes were quantified in 7 random samples.
Results:
Due to the instability of isoenzymes 4 and 5, a decrease in LDH was observed in the first 24h in samples maintained at -20 degrees C and after 2 days when maintained at 4 degrees C. Aside from glucose, all parameters were stable for up to at least day 4 when stored at room temperature or 4 degrees C.
Conclusions:
Temperature and storage time are potential preanalytical errors in pleural fluid analyses, mainly if we consider the instability of glucose and LDH. The ideal procedure is to execute all the tests immediately after collection. However, most of the tests can be done in refrigerated samples, excepting LDH analysis.
Related Concept Videos
Sample Handling
Samples should be transported carefully from collection points to the laboratory. They should be properly sealed and clearly labeled to prevent cross-contamination. To preserve the sample integrity, optimal temperature conditions during transport are essential. This could involve using...
Pleural Effusion I: Introduction
There are two main types of pleural effusion: transudative and exudative. They are differentiated using Light's criteria,...
Key Techniques in Microbiology
Factors Influencing Microbial Growth: Temperature
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...