Analysis of cocaine and benzoylecgonine in urine by using multisyringe flow injection analysis-gas chromatography-mass spectrometry system
Related Experiment Video
Updated: Jun 12, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
María del Rosario Brunetto1, Yelitza Delgado, Sabrina Clavijo
1Laboratorio de Espectroscopia Molecular Departamento de Química, Facultad de Ciencias, Universidad de Los Andes, Mérida, Venezuela. brunetto@ula.ve
Abstract:
In this paper, a method was described to determine cocaine (COC) and benzoylecgonine (BZE) in human urine samples by GC-MS detection. The extraction of analytes from urine samples was achieved in an Oasis hydrophilic-lipophilic balance column (20 mmx3.9 mm id, dp=25 microm; Waters, USA), incorporated in a multisyringe flow injection system, used for the sample treatment. Finally, to improve the volatility of the BZE, an in-line derivatization reaction with N,O-bis (trimethylsilyl) trifluoroacetamide with 1% trimethylchlorosilane was made microwave-assisted in order to reduce the reaction time. The results showed that the proposed method is a good alternative for the analysis of COC and BZE in urine samples because it offers advantages compared with those described in the literature, which include simplicity in the sample treatment, the sensitivity and selectivity necessary to determine the analytes of interest at low levels in the urine and high sample throughput.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
High-Performance Liquid Chromatography: Elution Process
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...