Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

IR Spectrometers01:25

IR Spectrometers

There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Raman Spectroscopy Instrumentation: Overview01:26

Raman Spectroscopy Instrumentation: Overview

A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Finding the target sites of RNA-binding proteins.

Wiley interdisciplinary reviews. RNA·2013
Same author

Phytoestrogen α-Zearalanol attenuates homocysteine-induced apoptosis in human umbilical vein endothelial cells.

BioMed research international·2013
Same author

High expression of APAF-1 elevates erythroid apoptosis in iron overload myelodysplastic syndrome.

Tumour biology : the journal of the International Society for Oncodevelopmental Biology and Medicine·2013
Same author

[Surgical treatment for long bone giant cell tumor of extremity with pathologic fracture].

Beijing da xue xue bao. Yi xue ban = Journal of Peking University. Health sciences·2013
Same author

Exploring the biologically relevant chemical space for drug discovery.

Journal of chemical information and modeling·2013
Same author

WW domain containing oxidoreductase induces apoptosis in gallbladder-derived malignant cell by upregulating expression of P73 and PUMA.

Tumour biology : the journal of the International Society for Oncodevelopmental Biology and Medicine·2013

Related Experiment Video

Updated: Jun 12, 2026

A Multimodal Wide-Field Fourier-Transform Raman Microscope
06:48

A Multimodal Wide-Field Fourier-Transform Raman Microscope

Published on: December 30, 2025

[Electro-optic modulation based study on spectrum resolution of static Fourier transform spectrometer].

Zheng-Min Yang1, Zhi-Chao Liu, Xiao Li

  • 1Photoelectric Information and Equipment Engineering Research Centers, North University of China, Taiyuan 030051, China.

Guang Pu Xue Yu Guang Pu Fen Xi = Guang Pu
|May 26, 2010
PubMed
Summary

Researchers enhanced static Fourier transform interferometer resolution by using electro-optic modulation in lithium niobate (LiNbO3) crystals. This method increases optical path difference without mechanical scanning, boosting spectrum resolution significantly.

More Related Videos

Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging
09:46

Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging

Published on: April 28, 2022

A Guide to Structured Illumination TIRF Microscopy at High Speed with Multiple Colors
11:15

A Guide to Structured Illumination TIRF Microscopy at High Speed with Multiple Colors

Published on: May 30, 2016

Related Experiment Videos

Last Updated: Jun 12, 2026

A Multimodal Wide-Field Fourier-Transform Raman Microscope
06:48

A Multimodal Wide-Field Fourier-Transform Raman Microscope

Published on: December 30, 2025

Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging
09:46

Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging

Published on: April 28, 2022

A Guide to Structured Illumination TIRF Microscopy at High Speed with Multiple Colors
11:15

A Guide to Structured Illumination TIRF Microscopy at High Speed with Multiple Colors

Published on: May 30, 2016

Area of Science:

  • Optics and Photonics
  • Materials Science

Context:

  • Static Fourier transform interferometers are crucial for spectral analysis.
  • Enhancing spectrum resolution in static interferometers without increasing instrument size is a key challenge.

Purpose:

  • To investigate the use of electro-optic modulation in a variable refractive index crystal (LiNbO3) to increase optical path difference and spectrum resolution in static interferometers.

Summary:

  • A static Fourier transform interferometer employed lithium niobate (LiNbO3) with electro-optic modulation, applying opposite phase modulation signals to enhance optical path difference.
  • Mathematical derivation showed that a refraction modulation of 0.030 could increase spectrum resolution by 16.7 times for the same instrument size.
  • Simulations indicated reduced refractive modulation at longer wavelengths, with increased optical path difference correlating with higher chi' values. Spectral distortion within the 500-1100 nm range was deemed manageable.

Impact:

  • This technique offers a method to improve spectrum resolution in static interferometers by increasing optical path difference without mechanical scanning.
  • The findings suggest a potential pathway for developing more sensitive and higher-resolution static interferometric systems.