Related Experiment Video
Updated: Jun 12, 2026

Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Pharyngeal oxygen administration increases the time to serious desaturation at intubation in acute lung injury: an
Joakim Engström1, Göran Hedenstierna, Anders Larsson
1Department of Anesthesiology and Intensive Care, Uppsala University, ANIVA ing 70 1tr, University hospital, S 75185 Uppsala, Sweden. joakim@me.com
Introduction:
Endotracheal intubation in critically ill patients is associated with severe life-threatening complications in about 20%, mainly due to hypoxemia. We hypothesized that apneic oxygenation via a pharyngeal catheter during the endotracheal intubation procedure would prevent or increase the time to life-threatening hypoxemia and tested this hypothesis in an acute lung injury animal model.
Methods:
Eight anesthetized piglets with collapse-prone lungs induced by lung lavage were ventilated with a fraction of inspired oxygen of 1.0 and a positive end-expiratory pressure of 5 cmH2O. The shunt fraction was calculated after obtaining arterial and mixed venous blood gases. The trachea was extubated, and in randomized order each animal received either 10 L oxygen per minute or no oxygen via a pharyngeal catheter, and the time to desaturation to pulse oximeter saturation (SpO2) 60% was measured. If SpO2 was maintained at over 60%, the experiment ended when 10 minutes had elapsed.
Results:
Without pharyngeal oxygen, the animals desaturated after 103 (88-111) seconds (median and interquartile range), whereas with pharyngeal oxygen five animals had a SpO2 > 60% for the 10-minute experimental period, one animal desaturated after 7 minutes, and two animals desaturated within 90 seconds (P < 0.016, Wilcoxon signed rank test). The time to desaturation was related to shunt fraction (R2 = 0.81, P = 0.002, linear regression); the animals that desaturated within 90 seconds had shunt fractions >40%, whereas the others had shunt fractions <25%.
Conclusions:
In this experimental acute lung injury model, pharyngeal oxygen administration markedly prolonged the time to severe desaturation during apnea, suggesting that this technique might be useful when intubating critically ill patients with acute respiratory failure.
More Related Videos
05:43Topical Airway Anesthesia for Awake-endoscopic Intubation Using the Spray-as-you-go Technique with High Oxygen Flow
Published on: January 13, 2017
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Cardiopulmonary Resuscitation II: ACLS Airway Management
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue, improving...