The relationship between nasalance scores and nasality ratings obtained with equal appearing interval and direct
Tami U Brancamp1, Kerry E Lewis, Thomas Watterson
1University of Nevada, School of Medicine, Department of Speech Pathology and Audiology, Reno, Nevada 89557, USA. tbrancamp@medicine.nevada.edu
Objectives:
To assess the nasalance/nasality relationship and Nasometer test sensitivity and specificity when nasality ratings are obtained with both equal appearing interval (EAI) and direct magnitude estimation (DME) scaling procedures. To test the linearity of the relationship between nasality ratings obtained from different perceptual scales. STIMULI: Audio recordings of the Turtle Passage.
Design:
Participants' nasalance scores and audio recordings were obtained simultaneously. A single judge rated the samples for nasality using both EAI and DME scaling procedures.
Participants:
Thirty-nine participants 3 to 17 years of age. Across participants, resonance ranged from normal to severely hypernasal.
Main Outcome Measures:
Nasalance scores and two nasality ratings.
Results:
The magnitude of the correlation between nasalance scores and EAI ratings of nasality (r = .63) and between nasalance and DME ratings of nasality (r = .59) was not significantly different. Nasometer test sensitivity and specificity for EAI-rated nasality were .71 and .73, respectively. For DME-rated nasality, sensitivity and specificity were .62 and .70, respectively. Regression of EAI nasality ratings on DME nasality ratings did not depart significantly from linearity.
Conclusions:
No difference was found in the relationship between nasalance and nasality when nasality was rated using EAI as opposed to DME procedures. Nasometer test sensitivity and specificity were similar for EAI- and DME-rated nasality. A linear model accounted for the greatest proportion of explained variance in EAI and DME ratings. Consequently, clinicians should be able to obtain valid and reliable estimates of nasality using EAI or DME.
Related Concept Videos
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between the...
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated. For...
Scaling
Estimation of the Physical Quantities
Ordinal Level of Measurement
Data measured using an ordinal scale are similar to nominal scale data, but there is one major difference. The ordinal scale data can be ordered. An example of ordinal scale data is a list of the top five national parks in the...
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and hence a...