Related Experiment Video
Updated: Jun 12, 2026

Acquiring Hyperpolarized 129Xe Magnetic Resonance Images of Lung Ventilation
Published on: November 21, 2023
Collateral ventilation in a canine model with bronchial obstruction: assessment with xenon-enhanced dual-energy CT
Eun Jin Chae1, Joon Beom Seo, Namkug Kim
1Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 388-1 Poongnap-dong, Songpa-gu, Seoul 138-736, Korea.
Purpose:
To determine the feasibility of the use of xenon-enhanced dynamic dual-energy computed tomography (CT) for visualization and quantitative assessment of collateral ventilation in a canine model with bronchial obstruction.
Materials And Methods:
This study was approved by the institutional animal care and use committee. One segmental bronchus was occluded in nine dogs (weight range, 20-25 kg). Dynamic dual-energy CT scanning was performed by using dual-source CT during the wash-in-washout study of xenon inhalation via mechanical ventilation. Imaging parameters were 14 x 1.2-mm collimation, 40 mAs (effective) at 140 kV and 170 mAs (effective) at 80 kV, pitch of 0.45, and 0.33-second rotation time. By using dual-energy software, CT images and xenon maps were reconstructed. CT attenuation values were measured in the airways proximal to obstruction (AW(PROX)) and airways distal to obstruction (AW(DIST)) and at the parenchyma with patent airways (P(PATE)) and parenchyma with obstructed airways (P(OBST)). CT attenuation values on dynamic xenon maps were plotted with exponential function; ventilation parameters, including velocity of ventilation (K value), magnitude of ventilation (A value), and time of arrival (TOA), were calculated on the basis of the Kety model.
Results:
In all animals, delayed and weaker xenon enhancement was identified at the airway and parenchyma distal to obstruction. For the A value, in the wash-in study, the differences between AW(PROX) and AW(DIST) and between P(PATE) and P(OBST) were significant (71.80 and 57.64, P = .05; 51.86 and 37.52 HU, P = .02). The K value of P(OBST) was lower than that of P(PATE) in the wash-in study (0.006 and 0 .010, P = .06). Mean and standard deviation for TOA were observed in the following increasing order: AW(PROX) ([3.50 +/- 7.70] x 10(-6) sec), P(PATE) (4.58 +/- 2.83), AW(DIST) (9.20 +/- 6.87), and P(OBST) (21.00 +/- 13.44).
Conclusion:
Collateral ventilation in a canine model with bronchial obstruction can be quantitatively assessed by using xenon-enhanced dynamic dual-energy CT.
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Cardiopulmonary Resuscitation II: ACLS Airway Management
