Related Experiment Video
Updated: Jun 12, 2026

A Porcine Model of Acute Respiratory Failure with a Continuous Infusion of Oleic Acid
Published on: March 8, 2024
[The source and factors that influence tracheal pulse oximetry signal]
Xiao-hua Fan1, Wei Wei, Jian Wang
1Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu 610041, China.
Objective:
To investigate the source and factors that influence tracheal pulse oximetry signal.
Methods:
The adult mongrel dog was intubated after anesthesia. The tracheal tube was modified by attaching a disposable pediatric pulse oximeter to the cuff. The chest of the dog was cut open and a red light from the tracheal oximeter was aligned with the deeper artery. The changes in tracheal pulse oxygen saturation (SptO2) signal were observed after the deeper artery was blocked temporarily. The photoplethysmography (PPG) and readings were recorded at different intracuff pressures. The influence of mechanical ventilation on the signal was also tested and compared with pulse oxygen saturation (SpO2).
Results:
The SptO2 signal disappeared after deeper artery was blocked. The SptO2 signal changed with different intracuff pressures (P < 0.001). Stronger SptO2 signal appeared under 20-60 cm H2O of intracuff pressure than under 0-10 cm H2O of intracuff pressure(P < 0.001). The PPG of SptO2 signal under a condition with mechanical ventilation differed from that without mechanical ventilation (P < 0. 01), which, was also different from SpO2 (P < 0.01).
Conclusion:
SptO2 signal is primarily derived from deeper arteries around the trachea, not from the tracheal wall. Both intracuff pressures and mechanical ventilation can influence SptO2 signal. The SptO2 signal under 20-60 cm H2O of intracuff pressure is stronger than that under 0-10 em H2O of intracuff pressure. Mechanical ventilation mainly changes PPG.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Special considerations while measuring pulse