Comparison of settings used for high-frequency chest-wall compression in cystic fibrosis
Robert R Kempainen1, Carlos Milla, Jordan Dunitz
1Department of Medicine, Hennepin County Medical Center, University of Minnesota School of Medicine, Mail Stop G-5, 701 Park Avenue, Minneapolis, MN 55415, USA. kempa001@umn.edu
Background:
Cystic fibrosis (CF) patients commonly use a high-frequency chest-wall compression (HFCWC) device for airway clearance that generates oscillatory flow with a sine-wave configuration. Typical HFCWC settings combine a lower Vest inflation pressure setting (eg, 5 on the Vest's arbitrary 1-10 scale for the setting that controls the background pressure of the inflatable vest) with mid-range frequency (14-16 Hz) (lower-pressure/mid-frequency HFCWC).
Objective:
To determine whether HFCWC with higher pressure settings (6-10 on the Hill-Rom Vest's arbitrary 1-10 scale) combined with variable mid-frequencies (8, 9, and 10 Hz, plus 18, 19, and 20 Hz) (higher-pressure/variable-frequency HFCWC) results in greater sputum expectoration than lower-pressure/mid-frequency HFCWC.
Methods:
This was a controlled randomized crossover study. Sixteen clinically stable, adult CF patients participated. Patients performed airway clearance with HFCWC, once each with lower-pressure/mid-frequency HFCWC and higher-pressure/variable-frequency HFCWC, on separate occasions. All sputum produced during each session was collected. Patients completed pulmonary function tests before and after each session.
Results:
Median sputum wet weight was greater with higher-pressure/variable-frequency HFCWC than with lower-pressure/mid-frequency HFCWC (6.4 g, range 0.49-22.0 g, versus 4.8 g, range 0.24-15.0 g, P = .02). Dry sputum weight differences did not reach statistical significance (higher-pressure/variable-frequency HFCWC 0.20 g, range 0.009-0.62 g, lower-pressure/mid-frequency HFCWC 0.12 g, range 0.0001-1.0 g, P = .23). Higher-pressure/variable-frequency HFCWC and lower-pressure/mid-frequency HFCWC resulted in similar increases in FEV(1) (70 mL vs 90 mL, P = .21) and forced vital capacity (80 mL vs 80 mL, P = .94). Post-therapy sputum viscoelastic properties did not differ. Patients perceived the 2 regimens as equally comfortable and effective (P = .35 and P = .35, respectively).
Conclusions:
In adult CF patients, single-session higher-pressure/variable-frequency HFCWC resulted in greater sputum expectoration by wet weight, but not other differences, compared to the commonly used lower-pressure/mid-frequency settings. Longer-term comparisons are needed in a larger, more diverse population to determine whether sustained use of the higher-pressure/variable-frequency settings results in clinically important differences in outcomes.
More Related Videos
Related Concept Videos
Cystic Fibrosis: Management
Sinus disease and chronic sinusitis...
Chest Physiotherapy
Purpose
CPT is primarily used for patients with excessive bronchial secretions who have difficulty clearing...
Cystic Fibrosis: Pathogenesis
CF is primarily caused by a genetic mutation in a chromosome 7 gene coding for the cystic fibrosis transmembrane conductance regulator (CFTR) protein. The most common gene mutation leading to CF is the ΔF508 mutation, but...
Mechanical Ventilation I: Indication and Settings
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...