Related Experiment Video
Updated: Jun 12, 2026

International Expert Consensus and Recommendations for Neonatal Pneumothorax Ultrasound Diagnosis and Ultrasound-guided Thoracentesis Procedure
Published on: March 12, 2020
Thoracic needle decompression for tension pneumothorax: clinical correlation with catheter length
Chad G Ball1, Amy D Wyrzykowski, Andrew W Kirkpatrick
1The Department of Surgery, Emory University, Grady Memorial Hospital, Atlanta, GA, USA. ball.chad@gmail.com
Background:
Tension pneumothorax requires emergent decompression. Unfortunately, some needle thoracostomies (NTs) are unsuccessful because of insufficient catheter length. All previous studies have used thickness of the chest wall (based on cadaver studies, ultrasonography or computed tomography [CT]) to extrapolate probable catheter effectiveness. The objective of this clinical study was to identify the frequency of NT failure with various catheter lengths.
Methods:
We evaluated the records of all patients with severe blunt injury who had a prehospital NT before arrival at a level-1 trauma centre over a 48-month period. Patients were divided into 2 groups: helicopter (4.5-cm catheter sheath) and ground ambulance (3.2 cm) transport. Success of the NT was confirmed by the absence of a large pneumothorax on subsequent thoracic ultrasonography and CT.
Results:
Needle thoracostomy decompression was attempted in 1.5% (142/9689) of patients. Among patients with blunt injuries, the incidence was 1.4% (101/7073). Patients transported by helicopter (74%) received a 4.5-cm sheath. The remainder (26% ground transport) received a 3.2-cm catheter. A minority in each group (helicopter 15%, ground 28%) underwent immediate chest tube insertion (before thoracic ultrasound) because of ongoing hemodynamic instability. Failure to decompress the pleural space by NT was observed via ultrasound and/or CT in 65% (17/26) of attempts with a 3.2-cm catheter, compared with only 4% (3/75) of attempts with a 4.5-cm catheter (p < 0.001).
Conclusion:
Tension pneumothorax decompression using a 3.2-cm catheter was unsuccessful in up to 65% of cases. When a larger 4.5-cm catheter was used, fewer procedures (4%) failed. Thoracic ultrasonography can be used to confirm NT placement.
Related Concept Videos
Pneumothorax-II
Clinical Manifestations:
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Pneumothorax II: Pathophysiology
Pneumothorax-I
Pneumothorax can be even further classified as spontaneous, traumatic, and tension pneumothorax.
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...