[Kt calculation as a quality indicator of haemodialysis adequacy]

M Molina Núñez1, S Roca Meroño, R M de Alarcón Jiménez

  • 1Servicio de Nefrología, Hospital Universitario Santa María del Rosell, Cartagena, Murcia. manuel.molina4@carm.es

The haemodialysis dose is a good marker of dialysis adequacy, and we usually monitor it with Kt/V measure. The dialysis dose monitored with Kt allows a better discrimination, detecting a percentage of the patients that perhaps do not get an adequate dose for their gender or body surface area after treatment with a minimum recommended dose of Kt/V. The objective of this study was to evaluate Kt as a clinical indicator referred to dialysis adequacy in the haemodialysis population. The aim was that more than 85% of the patients would achieve the recommended Kt target for their gender (at least 50 litres in men and 45 litres in women), or their body surface area. In each of the patients (mean 129) the Kt mean value was determined for three consecutive dialysis sessions, one every two months, during the follow-up period (14 months). At the beginning, the Kt/V value was on target (> 1.3) in 93.2% of the patients, but only in 58% according to Kt measure for their gender. After 4 months, we observed that 85% of patients' Kt target increased for their gender, but only 68% did if we used the Kt individualised for their body surface area. From month 6 to the end of the follow-up period, more than 85% of patients obtained an adequate Kt for their body surface area (p < 0.001). A significant increase of Kt mean (5.4 litres) was observed at the end of the study (p < 0.001). The usual dialysis prescription parameters were modified increasing blood flow rate (34.14 ml/min, p < 0.001), session effective duration (8.04 minutes, p < 0.001), dialyser surface area (24.1% of patients changed from helixone 1.3 to 1.6 m2, p < 0.001) and haemodialysis modality (56.8% of patients changed from conventional haemodialysis to on-line haemodiafiltration, p < 0.001). We conclude that monitoring dialysis dose with Kt is a good clinical measure of adequacy, and using it as a quality indicator can be done in line with the more demanding quality standards.

Related Concept Videos

Hemodialysis III: Nursing Management01:25

Hemodialysis III: Nursing Management

The nursing management of a patient undergoing hemodialysis includes several critical steps, starting with a thorough assessment before the procedure.Before the Hemodialysis ProcedureFirst, record the patient's vital signs—blood pressure, heart rate, respiratory rate, and temperature—to establish a baseline. This baseline is essential for detecting conditions such as hypotension that could impact the patient's response to dialysis. Document the patient's pre-dialysis weight, as this measurement...
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
Hemodialysis I: Introduction01:25

Hemodialysis I: Introduction

Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
Continuous Renal Replacement Therapy01:30

Continuous Renal Replacement Therapy

Continuous Renal Replacement Therapy, also known as CRRT, is a procedural treatment for acute kidney injury (AKI) that gradually removes uremic toxins and fluids while maintaining acid-base balance and stabilizing electrolytes. It is particularly useful for hemodynamically unstable patients. Unlike intermittent hemodialysis, which is faster, CRRT provides a gentler approach over 24 hours, closely mimicking the function of natural kidneys. However, CRRT is not ideal for patients with...
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration01:28

Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration

Glomerular filtration rate (GFR) can be estimated from serum creatinine using the modification of diet in renal disease (MDRD) formula or the chronic kidney disease–epidemiology collaboration (CKD–EPI) equation. Both methods are widely used in clinical practice to assess kidney function and guide treatment decisions.The MDRD equation does not require weight or height measurements and is normalized to the body surface area of 1.73 m², considered the average adult surface area. This equation is...
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy01:26

Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy

Continuous Renal Replacement Therapy (CRRT) is an essential intervention for patients experiencing severe kidney dysfunction. This therapy offers a continuous mechanism for removing fluids and toxins from the bloodstream, leveraging the patient’s blood pressure to facilitate filtration through a specialized filter. This method contrasts with intermittent dialysis, providing a gentler and more consistent removal of waste products and excess fluid, which is particularly beneficial in critically...