Related Experiment Video
Updated: Jun 12, 2026

Synthesis and Purification of Iodoaziridines Involving Quantitative Selection of the Optimal Stationary Phase for Chromatography
Published on: May 16, 2014
Extensive evaluation of a diffusion denuder technique for the quantification of atmospheric stable and radioactive
Ru-Jin Huang1, Xiaolin Hou, Thorsten Hoffmann
1Institute of Inorganic and Analytical Chemistry, Johannes Gutenberg-University of Mainz, D-55128 Mainz, Germany.
Abstract:
In this paper we present the evaluation and optimization of a new approach for the quantification of gaseous molecular iodine (I(2)) for laboratory- and field-based studies and its novel application for the measurement of radioactive molecular iodine. alpha-Cyclodextrin (alpha-CD) in combination with (129)I(-) is shown to be an effective denuder coating for the sampling of gaseous I(2) by the formation of an inclusion complex. The entrapped (127)I(2) together with the (129)I(-) spike in the coating is then released and derivatized to 4-iodo-N,N-dimethylaniline (4-I-DMA) for gas chromatography-mass spectrometry (GC-MS) analysis. The (127)I(2) collected can be differentiated from the (129)I(-) spike by MS. A set of parameters affecting the analytical performances of this approach, including amount of alpha-CD and (129)I(-) applied, denuder length, sampling gas flow rate and sampling duration, relative humidity, sample storage period, and condition of release and derivatization of iodine, is extensively evaluated and optimized. The collection efficiency is larger than 98% and the limit of detection (LOD) obtained is 0.17 parts-per-trillion-by-volume (pptv) for a sampling duration of 30 min at 500 mL min(-1). Furthermore, the potential use of this protocol for the determination of radioactive I(2) at ultra trace level is also demonstrated when (129)I(-) used in the coating is replaced by (127)I(-) and a multiple denuder system is used. Using the present method we observed 25.7-108.6 pptv (127)I(2) at Mweenish Bay, Ireland and 10(8) molecule m(-3 129)I(2) at Mainz, Germany.
More Related Videos
07:28An Efficient Method for Selective Desalination of Radioactive Iodine Anions by Using Gold Nanoparticles-Embedded Membrane Filter
Published on: July 13, 2018
11:38In situ FTIR Spectroscopy as a Tool for Investigation of Gas/Solid Interaction: Water-Enhanced CO2 Adsorption in UiO-66 Metal-Organic Framework
Published on: February 1, 2020
Related Concept Videos
Redox Titration: Iodimetry and Iodometry
Volatilization
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Atomic Absorption Spectroscopy: Atomization Methods
Gas Chromatography: Types of Detectors-II
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...