Dose reconstruction for volumetric modulated arc therapy (VMAT) using cone-beam CT and dynamic log files
Jianguo Qian1, Louis Lee, Wu Liu
1Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA 94305, USA.
None:
Volumetric modulated arc therapy (VMAT) has recently emerged as a new clinical modality for conformal radiation therapy. The aim of this work is to establish a methodology and procedure for retrospectively reconstructing the actual dose delivered in VMAT based on the pre-treatment cone-beam computed tomography (CBCT) and dynamic log files. CBCT was performed before the dose delivery and the system's log files were retrieved after the delivery. Actual delivery at a control point including MLC leaf positions, gantry angles and cumulative monitor units (MUs) was recorded in the log files and the information was extracted using in-house developed software. The extracted information was then embedded into the original treatment DICOM-radiation therapy (RT) file to replace the original control point parameters. This reconstituted DICOM-RT file was imported into the Eclipse treatment planning system (TPS) and dose was computed on the corresponding CBCT. A series of phantom experiments was performed to show the feasibility of dose reconstruction, validate the procedure and demonstrate the efficacy of this methodology. The resultant dose distributions and dose-volume histograms (DVHs) were compared with those of the original treatment plan. The studies indicated that CBCT-based VMAT dose reconstruction is readily achievable and provides a valuable tool for monitoring the dose actually delivered to the tumor target as well as the sensitive structures. In the absence of setup errors, the reconstructed dose shows no significant difference from the original pCT-based plan. It is also elucidated that the proposed method is capable of revealing the dosimetric changes in the presence of setup errors. The method reported here affords an objective means for dosimetric evaluation of VMAT delivery and is useful for adaptive VMAT in future.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...