Related Experiment Video
Updated: Jun 12, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Thermal necrosis after simultaneous tibial osteotomy and total knee arthroplasty using press-fit extension-stem
Kazunari Ishida1, Nobuhiro Tsumura, Koji Takayama
1Department of Orthopaedic Surgery, Hyogo Rehabilitation Centre Center Hospital, 1070 Akebono-cho, Nishi-ku, Kobe 651-2181, Japan. wavedreamer17@yahoo.co.jp
Abstract:
One-staged tibial corrective osteotomy and total knee arthroplasty is a challenging but effective treatment for arthritic knees with extra-articular deformity. Although osteocutaneous thermal necrosis is accepted as a complication of intramedullary reamed nailing following long bone fractures, only 15 cases have been reported in the English literature at present. This report illustrates a rare case of thermal necrosis in a patient undergoing tibial corrective osteotomy coincident with long-stemmed total knee arthroplasty. Excessive reaming with a machine reamer is hypothesized as the cause of this serious complication. In this report, we highlight this rare but serious complication after long-stemmed total knee arthroplasty.