Speech effects of a speaking valve versus external PEEP in tracheostomized ventilator-dependent neuromuscular
Hélène Prigent1, Marine Garguilo2, Sophie Pascal2
1Services de Physiologie, Explorations Fonctionnelles, Réanimation Médicale, Rééducation Fonctionnelle, et Centre d'Investigation Clinique et d'Innovation Technologique (Inserm Unit 805), Hôpital Raymond Poincaré, AP-HP, 92380, Garches, France. helene.prigent@rpc.ap-hop-paris.fr.
Purpose:
Many patients with respiratory failure related to neuromuscular disease receive chronic invasive ventilation through a tracheostomy. Improving quality of life, of which speech is an important component, is a major goal in these patients. We compared the effects on breathing and speech of low-level positive end-expiratory pressure (PEEP, 5 cmH(2)O) and of a Passy-Muir speaking valve (PMV) during assist-control ventilation.
Methods:
We studied ten patients with neuromuscular disorders, between December 2008 and April 2009. Flow was measured using a pneumotachograph. Microphone speech recordings were subjected to both quantitative measurements and qualitative assessments; the latter consisted of both an intelligibility score (using a French adaptation of the Frenchay Dysarthria Assessment) and a perceptual score determined by two speech therapists.
Results:
Text reading time, perceptive score, intelligibility score, speech comfort, and respiratory comfort were similar with PEEP and PMV. During speech with 5 cmH(2)O PEEP, six of the ten patients had no return of expiratory gas to the expiratory line and, therefore, had the entire insufflated volume available for speech, a condition met during PMV use in all patients. During speech, the respiratory rate increased by at least 3 cycles/min above the backup rate in seven patients with PEEP and in none of the patients with PMV.
Conclusions:
Low-level PEEP is as effective as PMV in ensuring good speech quality, which might be explained by sealed expiratory line with low-level PEEP and/or respiratory rate increase during speech with PEEP observed in most of the patients.
Related Concept Videos
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...