Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Gauss's Law: Spherical Symmetry01:26

Gauss's Law: Spherical Symmetry

A charge distribution has spherical symmetry if the density of charge depends only on the distance from a point in space and not on the direction. In other words, if the system is rotated, it doesn't look different. For instance, if a sphere of radius R is uniformly charged with charge density ρ0, then the distribution has spherical symmetry. On the other hand, if a sphere of radius R is charged so that the top half of the sphere has a uniform charge density ρ1 and the bottom half has a uniform...
Atomic Orbitals02:44

Atomic Orbitals

An atomic orbital represents the three-dimensional regions in an atom where an electron has the highest probability to reside. The radial distribution function indicates the total probability of finding an electron within the thin shell at a distance r from the nucleus. The atomic orbitals have distinct shapes which are determined by l, the angular momentum quantum number. The orbitals are often drawn with a boundary surface, enclosing densest regions of the cloud.
Nuclear Overhauser Enhancement (NOE)01:06

Nuclear Overhauser Enhancement (NOE)

Irradiation of a spin-active nucleus causes an increase or decrease in the signal intensity of neighboring nuclei that are not necessarily chemically bonded or involved in J-coupling. This phenomenon, called the nuclear Overhauser enhancement (NOE), results from through-space interactions between the nuclear spins. The NOE effect decreases with increasing internuclear distance and is generally not observed beyond 4 angstroms. In NOE, dipole-dipole interactions between neighboring spin-active...
Atomic Nuclei: Nuclear Spin State Population Distribution01:14

Atomic Nuclei: Nuclear Spin State Population Distribution

Near absolute zero temperatures, in the presence of a magnetic field, the majority of nuclei prefer the lower energy spin-up state to the higher energy spin-down state. As temperatures increase, the energy from thermal collisions distributes the spins more equally between the two states. The Boltzmann distribution equation gives the ratio of the number of spins predicted in the spin −½ (N−) and spin +½ (N+) states.
X-ray Imaging01:24

X-ray Imaging

German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with X-rays, and by 1900, X-ray was widely...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

<i>APOE ε4</i> and Alzheimer's disease biomarkers in an American Indian community.

Alzheimer's & dementia (Amsterdam, Netherlands)·2026
Same author

Structural connectome analysis using a graph-based deep model for prediction of non-imaging variables.

Frontiers in neuroscience·2026
Same author

Frame-wise multi-echo distortion correction for superior functional MRI.

Imaging neuroscience (Cambridge, Mass.)·2026
Same author

Predictive acoustical processing in human cortical layers.

Nature communications·2026
Same author

An 80-channel receive array for 10.5T neuroimaging: Key considerations for SNR optimization.

bioRxiv : the preprint server for biology·2026
Same author

DEEP-LEARNING CORTICAL REGISTRATION GUIDED BY STRUCTURAL AND DIFFUSION MRI AND CONNECTIVITY.

Proceedings. IEEE International Symposium on Biomedical Imaging·2026

Related Experiment Video

Updated: Jun 12, 2026

In situ Grazing Incidence Small Angle X-ray Scattering on Roll-To-Roll Coating of Organic Solar Cells with Laboratory X-ray Instrumentation
06:49

In situ Grazing Incidence Small Angle X-ray Scattering on Roll-To-Roll Coating of Organic Solar Cells with Laboratory X-ray Instrumentation

Published on: March 2, 2021

Reconstruction of the orientation distribution function in single- and multiple-shell q-ball imaging within constant

Iman Aganj1, Christophe Lenglet, Guillermo Sapiro

  • 1Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, Minnesota, USA. iman@umn.edu

Magnetic Resonance in Medicine
|June 11, 2010
PubMed
Summary

This study introduces a new q-Ball imaging method to accurately calculate orientation distribution functions by incorporating the solid angle factor. This improves the normalization and sharpness of diffusion MRI results without postprocessing.

More Related Videos

Assembly and Characterization of Polyelectrolyte Complex Micelles
08:44

Assembly and Characterization of Polyelectrolyte Complex Micelles

Published on: March 2, 2020

Quantitative Optical Microscopy: Measurement of Cellular Biophysical Features with a Standard Optical Microscope
14:09

Quantitative Optical Microscopy: Measurement of Cellular Biophysical Features with a Standard Optical Microscope

Published on: April 7, 2014

Related Experiment Videos

Last Updated: Jun 12, 2026

In situ Grazing Incidence Small Angle X-ray Scattering on Roll-To-Roll Coating of Organic Solar Cells with Laboratory X-ray Instrumentation
06:49

In situ Grazing Incidence Small Angle X-ray Scattering on Roll-To-Roll Coating of Organic Solar Cells with Laboratory X-ray Instrumentation

Published on: March 2, 2021

Assembly and Characterization of Polyelectrolyte Complex Micelles
08:44

Assembly and Characterization of Polyelectrolyte Complex Micelles

Published on: March 2, 2020

Quantitative Optical Microscopy: Measurement of Cellular Biophysical Features with a Standard Optical Microscope
14:09

Quantitative Optical Microscopy: Measurement of Cellular Biophysical Features with a Standard Optical Microscope

Published on: April 7, 2014

Area of Science:

  • Medical Imaging
  • Diffusion MRI
  • Neuroscience

Background:

  • q-Ball imaging is a high-angular-resolution diffusion imaging technique for resolving intravoxel fiber orientations.
  • Standard orientation distribution function computation uses linear radial projection, neglecting volume element changes, leading to inaccurate results.

Purpose of the Study:

  • To propose a new technique for calculating the orientation distribution function (ODF) in q-Ball imaging.
  • To address the limitations of standard methods, including normalization and sharpness issues.

Main Methods:

  • Incorporated the solid angle factor into the ODF calculation for mathematical correctness.
  • Developed a flexible model for ODF estimation from single or multiple q-shell datasets.
  • Utilized a multiexponential diffusion signal model for multi-shell acquisitions.

Main Results:

  • Achieved a dimensionless and normalized ODF expression.
  • Demonstrated improved performance on artificial data and 7-T MRI scans.
  • Eliminated the need for postprocessing steps like artificial sharpening.

Conclusions:

  • The proposed method provides a more accurate and robust estimation of ODFs in diffusion MRI.
  • This advancement enhances the analysis of complex white matter architectures.
  • The technique is applicable to both single and multi-shell q-Ball imaging data.