Related Experiment Video
Updated: Jun 12, 2026

Non-Invasive Visualization of Nailbed Microvascular Morphology in Mice Using Capillaroscopy
Published on: February 28, 2025
Nail-fold capillary abnormalities are associated with anti-centromere antibody and severity of digital ischaemia
Ariane L Herrick1, Tonia L Moore, Andrea K Murray
1The University of Manchester, Manchester Academic Health Science Centre, Salford Royal NHS Foundation Trust, Salford M6 8HD, UK. ariane.herrick@manchester.ac.uk
Objectives:
Advances in nail-fold capillaroscopy allow capillary abnormalities to be quantified. Our aim was to investigate, in patients with SSc, the relationships between the degree of nail-fold capillary abnormality and disease subtypes (lcSSc and dcSSc), duration of RP and the presence of (i) severe digital ischaemia (as defined by previous i.v. vasodilators, debridements or amputations), (ii) a positive ACA, (iii) clinically evident calcinosis, (iv) pulmonary arterial hypertension and (v) telangiectases.
Methods:
This was a retrospective study of 176 patients. Six capillary measurements (four semi-automated and two manual) were calculated (automated width, distance between capillaries, tortuosity and derangement, and manual distance and density). Relationships between these measurements and the different clinical features of SSc were examined using multiple linear regressions (adjusted for age, sex and smoking status).
Results:
One hundred and forty-two patients had lcSSc and 34 had dcSSc. Sixty-eight (39%) had a history of severe digital ischaemia, 66 (38%) were anti-centromere positive, 53 (30%) had clinically evident calcinosis and 26 (15%) had an estimated pulmonary artery pressure of >30 mmHg. Positive associations were found between both automated and manually measured distance between capillaries and (i) presence of severe digital ischaemia and (ii) positive ACA, and reduced density was also associated with positive anti-centromere. Patients with moderate/severe telangiectases had wider capillaries compared with those with 'mild' lesions.
Conclusions:
Both severe digital ischaemia and positive ACA are associated with measurable nail-fold capillaroscopic change, which has the potential of being an outcome measure for the structural microvascular disease associated with SSc-spectrum disorders.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Accessory Structures of the Skin: Nails
The main components of a nail include the following.
Nail Plate: The nail plate is the visible portion of the nail that extends beyond the fingertips or toes. It is a hard, translucent...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Endocarditis II: Clinical Features of Infective Endocarditis
Peripheral Artery Disease I: Introduction