Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Lower interbreath interval complexity is associated with extubation failure in mechanically ventilated patients
Christopher E White1, Andriy I Batchinsky, Corina Necsoiu
1U.S. Army Institute of Surgical Research, 3400 Rawley E. Chambers Avenue, Fort Sam Houston, TX 78234, USA. christopher.eric.white@us.army.mil
Objective:
To determine whether lower complexity of interbreath interval as measured with nonlinear analysis techniques will identify patients who fail to separate from mechanical ventilation after 30-minute spontaneous breathing trials (SBTs).
Methods:
Respiratory waveforms from SBT of patients in surgical or burn intensive care units were recorded for later analysis. The decision to extubate was made by attending physician. Extubated patients were observed for 48 hours; during this time, reintubation or noninvasive positive pressure ventilation was considered as a failure. Analysis of waveform data by software was performed post hoc. Sample entropy (SampEn) and other nonlinear measures were 48 hours of extubation.
Results:
Thirty-two patients (24 burn, 8 trauma/surgical admissions; mean age, 40.2 +/- 16.9 years; 26 men and 6 women) who were intubated >24 hours were extubated after SBT. Twenty-four patients were successfully separated from mechanical ventilation and eight failed. Age, gender, and mechanism of injury did not influence outcome. SampEn calculated for the two groups presented in this study was different with the cohort that failed extubation having a lower mean value (1.35 +/- 0.39 vs. 1.87 +/- 0.27; p < 0.001). Other nonlinear metrics were moved in concert with SampEn. The stationarity in the respiratory signal was not different between groups.
Conclusion:
In intubated patients, the interbreath interval in those who were successfully separated from mechanical ventilation was more irregular than those who failed, as measured by nonlinear techniques. When available at bedside, these metrics may be useful markers of pulmonary health and assist in clinical decision making.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Respiratory Volumes and Capacities I
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: