Objective:
To explore the imaging value of digital subtraction technique on head and neck with 64-slice spiral CTA.
Methods:
958 patients of head and neck vessels were examined with the direct method, Surestart law, low-dose tes methods, Surestart subtraction method, low-dose test subtraction method by CTA, the former three kinds are non-subtraction method, the latter two kinds are subtraction method, a comparative analysis on the five methods from the image quality, imaging time, imaging values, seek for the CTA method with optimal image quality, the shortest imaging time, the best value.
Results:
The image quality with the direct method (2.82 points), Surestart law (3.25 points), low-dose test method (3.33 points), Surestart subtraction method (4.10 points), low-dose test subtraction method (4.18 points), gradually changed well in order, the image quality of subtraction method is better than non-subtraction method; imaging time with direct method (40.26 minutes), Surestart law (35.06 minutes), small dose test method (33.49 minutes), Surestart subtraction method (17.52 minutes), small dose test subtraction method (15.32 minutes), gradually become shorter in order, the imaging time of subtraction method is shorter than the non-subtraction method; Evaluation on the sensitivity of aneurysms and stenosis, subtraction method is more better than the non-subtraction method, the little narrow extent and the smaller aneurysm, the subtraction method is more better than non-subtraction method.
Conclusion:
The digital subtraction method is an ideal head and neck imaging method with 64-slice spiral CTA.
More Related Videos
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
08:41Patient-Specific Polyvinyl Alcohol Phantom Fabrication with Ultrasound and X-Ray Contrast for Brain Tumor Surgery Planning
Published on: July 14, 2020
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT