Separation of heart sound signal from noise in joint cycle frequency-time-frequency domains based on fuzzy detection
Hong Tang1, Ting Li, Yongwan Park
1Department of Biomedical Engineering, Faculty of Electronic Information and Electrical Engineering, Dalian University of Technology, Dalian 116024, China. tanghong@dlut.edu.cn
Abstract:
Noise is generally unavoidable during recordings of heart sound signal. Therefore, noise reduction is one of the important preprocesses in the analysis of heart sound signal. This was achieved in joint cycle frequency-time-frequency domains in this study. Heart sound signal was decomposed into components (called atoms) characterized by time delay, frequency, amplitude, time width, and phase. It was discovered that atoms of heart sound signal congregate in the joint domains. On the other hand, atoms of noise were dispersed. The atoms of heart sound signal could, therefore, be separated from the atoms of noise based on fuzzy detection. In a practical experiment, heart sound signal was successfully separated from lung sounds and disturbances due to chest motion. Computer simulations for various clinical heart sound signals were also used to evaluate the performance of the proposed noise reduction. It was shown that heart sound signal can be reconstructed from simulated complex noise (perhaps non-Gaussian, nonstationary, and colored). The proposed noise reduction can recover variations in the both waveform and time delay of heart sound signal during the reconstruction. Correlation coefficient and normalized residue were used to indicate the closeness of the reconstructed and noise-free heart sound signal. Correlation coefficient may exceed 0.90 and normalized residue may be around 0.10 in 0-dB noise environment, even if the phonocardiogram signal covers only ten cardiac cycles.
More Related Videos
Related Concept Videos
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
Classification of Signals
A continuous-time signal holds a value at every instant in time, representing information seamlessly. In contrast, a discrete-time signal holds values only at specific moments, often denoted as x(n), where...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...
IR Frequency Region: Fingerprint Region
The...
Discrete Fourier Transform