Related Experiment Video
Updated: Jun 12, 2026

Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy (iPALM)
Published on: December 1, 2016
[Stability analysis of on-board calibration system of spatially modulated imaging Fourier transform spectrometer]
Jingz Gao1, Zhong-Ying Ji, Zhong-Hou Wang
1Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an 710119, China. gaojing@opt.ac.cn
Abstract:
Spatially modulated imaging Fourier transform spectrometer (SMIFTS) was an instrument that depended on interference, and after calibration, the reconstruction spectrum can quantificationally reflect the diffuse reflection of target under sunshine. On-board calibration of SMIFTS confirmed the change of SMIFTS according to relative spectrum calibration, inspected long-time attenuation of SMIFTS optical system, and corrected export data of SMIFTS. According to the requirement of remote sensor application, it must stay in vacuum environment for a long time. As a radiant standard, the stability of lamp-house in long time is the most important characteristic of on-board calibration system. By calculation and experimentation, analyses of on-board calibration of SMIFTS, and testing spaceflight environment characteristic of on-board calibration, the difficulty in the key parts of on-board calibration of SMIFTS such as lamp-house, spectrum filter and integrating sphere was solved. According to the radiation-time stability testing for lamp-house and optics, particle-radiation testing, environmental-mechanics testing and hot vacuum examination, good result was obtained. By whole-aperture and part-field comparative wavelength calibration, the spectrum curve and before-launch interferogram were obtained. After comparison with reconstruction spectrum under different condition, the stability and credibility of SMIFTS on-board calibration system was proved.
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Stability
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...

