A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)
Published on: July 11, 2017
Approach to measure isotopic ratios in species using multicollector-ICPMS coupled with chromatography
Vladimir N Epov1, Sylvain Berail, Maria Jimenez-Moreno
1LCABIE, IPREM, Université de Pau et des Pays de l'Adour/CNRS UMR 5254, Hélioparc, 2 Avenue du Président Pierre Angot, Pau, 64053, France. vladimir.epov@univ-pau.fr
Abstract:
A new approach was demonstrated for the isotope ratio measurement in different elemental species of Hg using transient signal obtained by chromatography coupled with multicollector-inductively coupled plasma mass spectrometry (MC-ICPMS). The method based on the slope of linear regression by transient intensities of different isotopes shows improved accuracy and reproducibility (0.2-0.5 per thousand as 2 standard deviation (SD)). Internal precision (RSD) of the method is very close to the theoretical value given by the counting statistic and is better by a factor of 6 in comparison with previous conventional methods of calculation. We demonstrated that internal RSD (uncertainty) depends on regression coefficients of the linear function (R(2)). The typical internal precision of isotopic ratio measurements (0.003-0.02%) was achieved for delta(202)Hg when injecting as low as 90 pg of Hg species. With the new methodology, it is possible to (i) measure the isotopic composition when a sample and a bracketing standard have significantly different concentrations, (ii) measure the isotopic composition of different species in samples versus single species in a bracketing standard, and (iii) measure the isotopic ratios for low abundant isotopes. We demonstrated application of this method for different environmental samples and processes.
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Ion-Exchange Chromatography
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.