Related Experiment Video
Updated: Jun 12, 2026

External Cephalic Version: Is it an Effective and Safe Procedure?
Published on: June 6, 2020
How often is a low Apgar score the result of substandard care during labour?
S Berglund1, H Pettersson, S Cnattingius
1Department of Clinical Science and Education, Karolinska Institutet Södersjukhuset, Stockholm, Sweden.
Abstract:
Please cite this paper as: Berglund S, Pettersson H, Cnattingius S, Grunewald C. How often is a low Apgar score the result of substandard care during labour? BJOG 2010;117:968-978. Objective To increase our knowledge of the occurrence of substandard care during labour. Design A population-based case-control study. Setting Stockholm County. Population Infants born in the period 2004-2006 in Stockholm County. Methods Cases and controls were identified from the Swedish Medical Birth Register, had a gestational age of >/=33 complete weeks, had planned for a vaginal delivery, and had a normal cardiotocographic (CTG) recording on admission. We compared 313 infants with an Apgar score of <7 at 5 minutes of age with 313 randomly selected controls with a full Apgar score, matched for year of birth. Main outcome measure Substandard care during labour. Results We found that 62% of cases and 36% of controls were subject to some form of substandard care during labour. In half of the cases and in 12% of the controls, CTG was abnormal for >/=45 minutes before birth. Fetal blood sampling was not performed in 79% of both cases and controls, when indicated. Oxytocin was provided without signs of uterine inertia in 20% of both cases and controls. Uterine contractions were hyperstimulated by oxytocin in 29% of cases and in 9% of controls, and the dose of oxytocin was increased despite abnormal CTG in 19% and 6% of cases and controls, respectively. Assuming that substandard care is a risk factor for low Apgar score, we estimate that up to 42% of the cases could be prevented by avoiding substandard care. Conclusions There was substandard care during labour of two-thirds of infants with a low Apgar score. The main reasons for substandard care were related to misinterpretation of CTG, not acting on an abnormal CTG in a timely fashion and incautious use of oxytocin.
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
SBAR II: Application of SBAR
SBAR Report from a Nurse to a Health Care Provider
S: "Hello, Dr. Smith. This is Jane, RN, from the Med Surg unit. I am calling to tell you about Ms. White in Room 210, who is experiencing increased pain and redness at her incision site. Her recent...
Aneurysm IV: Nursing Management
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
