Related Experiment Video
Updated: Jun 12, 2026

Application and Methodology of the Non-destructive 19F Time-domain NMR Technique to Measure the Content in Fluorine-containing Drug Products
Published on: August 22, 2017
Development of a method for nondestructive NIR transmittance spectroscopic analysis of acetaminophen and caffeine
Masatomo Ito1, Tatsuya Suzuki, Shuichi Yada
1PAT Committee, Japan Society of Pharmaceutical Machinery and Engineering, Miyoshi Bld 3F, 2-7-3 Kandata-cho, Chiyoda-ku, Tokyo 101-0046, Japan. ito.masatomo.id@daiichisankyo.co.jp
Abstract:
Calibration models for nondestructive NIR analysis of API (active pharmaceutical ingredient) contents in two separate layers of intact bilayer tablets were established. These models will enable the use of NIR transmittance spectroscopy in bilayer tableting processes for the control of API contents in separate layers. Acetaminophen and caffeine anhydrate were used as APIs, and tablets were made by the direct compression method. Their NIR spectra were measured in the transmittance mode. The reference assay was performed by HPLC. Calibration models were generated by the partial least-squares (PLS) regression. The initial calibration generated models with insufficient linearity and accuracy because the fluctuation range of tablet thickness was excessively large and irrelevant information on the thickness fluctuation was included in the models. By narrowing the fluctuation range to determine the proper range for acceptable prediction accuracy, it was confirmed that calibration models with less irrelevant information can be generated when the range was 4.30+/-0.06 mm or narrower. Furthermore, the fluctuation range of 4.30+/-0.06 mm was considered to be empirically valid in covering the fluctuation actually observed in ordinary tableting processes. Thus, the sample tablets within this range were used to generate the final calibration models, and calibration models sufficient in linearity and accuracy were established. In addition, it was proven that controlling the irradiated side was unnecessary. Namely, it is not necessary to keep the same side of sampled tablets for the online NIR analysis during bilayer tableting. It is useful, in order to obtain adequate calibration models, to evaluate the variable factors that affect the linearity and accuracy of the generated models and restrict the range of models or use a subset of prepared samples. Loading vectors, explained variances, and correlation coefficients between components and scores are important for the evaluation of variable factors.
Related Concept Videos
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...
Noncompartmental Analysis: Mean Transit, Absorption and Dissolution Time
One of the key parameters is the mean transit time (MTT), which refers to the total duration required for drug molecules to transit through the body. MTT is determined by calculating the ratio of the area under the moment curve to the area...
Methods for Studying Drug Absorption: In situ
The Doluisio method involves perfusing a prepared segment of a rat's small intestine with a solution of radiolabeled drug and a non-absorbable marker. This helps to differentiate between absorbed and non-absorbed drug concentrations. The intestinal segment is connected at both ends using tubing and syringes,...
Factors Influencing Drug Absorption: Pharmaceutical Parameters
In Vitro Drug Dissolution: Alternative Methods
In Vitro Drug Dissolution: Compendial Testing Models II

