Related Experiment Video
Updated: Jun 12, 2026

Experimental System of Solar Adsorption Refrigeration with Concentrated Collector
Published on: October 18, 2017
Dielectric compound parabolic concentrating solar collector with a frustrated total internal reflection absorber
Abstract:
Coupling a dielectric compound parabolic concentrator (DCPC) to an absorber across a vacuum gap by means of frustrated total internal reflection (FTIR) can theoretically approach the maximum concentration permitted by physical laws, thus allowing higher radiative fluxes in thermal applications. The calculated optical performance of 2-D DCPCs with FTIR absorbers indicates that the ratio of gap thickness to optical wavelength must be <0.22 before the optical performance of the DCPC is superior to that of the nondielectric CPC.
More Related Videos
12:08Fabrication of High Contrast Gratings for the Spectrum Splitting Dispersive Element in a Concentrated Photovoltaic System
Published on: July 18, 2015
09:00Indoor Experimental Assessment of the Efficiency and Irradiance Spot of the Achromatic Doublet on Glass (ADG) Fresnel Lens for Concentrating Photovoltaics
Published on: October 27, 2017
Related Concept Videos
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Total Internal Reflection Fluorescence Microscopy
Reflective Property of Parabolas