Related Experiment Video
Updated: Jun 12, 2026

Electroencephalographic Signal Acquisition Framework for Neurodiverse: A Case Study of Dolphin-Assisted Therapy
Published on: June 27, 2025
Analysis and classification of broadband echoes using bio-inspired dolphin pulses
Yan Pailhas1, Chris Capus, Keith Brown
1Oceans Systems Laboratory, School of EPS, Heriot-Watt University, Edinburgh, Scotland EH14 4AS, United Kingdom.
Abstract:
To date most sonars use narrow band pulses and often only the echo envelope is used for object detection and classification. This paper considers the advantages afforded by bio-inspired sonar for object identification and classification through the analysis and the understanding of the broadband echo structure. Using the biomimetic dolphin based sonar system in conjunction with bio-inspired pulses developed from observations of bottlenose dolphins performing object identification tasks, results are presented from experiments carried out in a wave tank and harbor. In these experiments responses of various targets to two different bio-inspired signals are measured and analyzed. The differences in response demonstrate the strong dependency between signal design and echo interpretation. In the simulations and empirical data, the resonance phenomena of these targets cause strong notches and peaks in the echo spectra. With precision in the localization of these peaks and dips of around 1 kHz, the locations are very stable for broadside insonification of the targets and they can be used as features for classification. This leads to the proposal of a broadband classifier which operates by extracting the notch positions in the target echo spectra.
Related Concept Videos
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case, then the...
Convergent Evolution
Doppler Effect - II
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Propagation of Waves
Consider a scenario where a wave propagates from a string of low linear mass density to a string of high linear mass density. In such a case, the reflected wave is out of phase with respect to the incident wave, however the...
Perception of Sound Waves
The pitch of a sound depends on the frequency and the pressure amplitude of the source. Two sounds of the same frequency...

