Current uses of transfusion administration sets: a cause for concern?
M J Nightingale1, D R Norfolk, D J Pinchon
1NHS Blood and Transplant, Southampton, UK. mark.nightingale@nbs.nhs.uk
Abstract:
There is potential for inappropriate use of transfusion administration sets when used in combination with modern infusion pumps with consequences for patient safety. The aims of our study were to (i) establish if the design and testing of transfusion sets specified in International Standard ISO 1135-4 are adequate for their current applications, (ii) identify if infusion pumps currently supplied in the UK for blood component administration are suitable for this purpose and (iii) determine the additional control measures needed to be applied by manufacturers and users to ensure patient safety. Keyword literature search was carried out to review and correlate important transfusion parameters with resultant adverse effects. Units for occlusion pressure, flow rate and haemolysis were standardised for ease of comparison. A sample of transfusion set instructions for use was reviewed. Principal suppliers of infusion pumps to the UK market were surveyed to identify those sold for blood transfusion, their recommended operating parameters and compatible transfusion sets. Previous work showed clinically unacceptable haemolysis at pressures above 40 kPa. Modern infusion pumps operate under negative pressures of up to 210 kPa. ISO 1135-4 design and test requirements do not match this performance and in particular omit testing under negative pressure. Transfusion sets surveyed did not indicate flow or pressure restrictions or specify the blood components with which they had been validated. ISO 1135-4 requires updating and has been initiated. Meanwhile, recommendations are made for transfusion set manufacturers concerning pressure limitations and restrictions on blood component type and for users concerning purchase, configuration and validation of infusion pumps and disposables.
Related Concept Videos
Blood Transfusion and Agglutination
History
The history of blood transfusion dates back to the 17th century, when early attempts were made in animals. In 1818 James Blundell, a British doctor, performed the first successful human blood transfusion. Later in 1900, Karl...
Blood Transfusion
Blood Transfusion Overview
A blood transfusion is a medical procedure used to replace blood lost due to injury, surgery, or to treat conditions such as anemia or cancer. During a transfusion, donor blood is...
Tissue Transplantation
The Biology of Tissue Transplantation
The biology of tissue transplantation hinges on the Major Histocompatibility Complex (MHC) molecules. These molecules...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Errors occurring during blood pressure monitoring
Several factors...