Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
Spectrophotometry: Introduction01:16

Spectrophotometry: Introduction

Spectrophotometry is the quantitative measurement of the absorption, reflection, diffraction, or transmission of electromagnetic radiation through a material as a function of the intensity and wavelength of the radiation. A spectrophotometer is a device used to measure the change in the radiation intensity caused by its interaction with the material.
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Mass Analyzers: Overview01:13

Mass Analyzers: Overview

The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
Chromatographic Resolution01:15

Chromatographic Resolution

In chromatography, a solute moves through a chromatographic column and tends to spread, forming a Gaussian-shaped band. The longer the solute spends in the column, the broader the band becomes. The broadening can lead to overlaps within the column, affecting separation effectiveness.
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Changes in serum concentrations of soluble vascular endothelial growth factor receptor-1 after pregnancy.

Human reproduction (Oxford, England)·2010
Same author

Measurement of the photoemission of two electrons from a multialkali photocathode.

Applied optics·2010
Same author

Tests performed with the improved MEGA spectrometer.

Applied optics·2010
Same author

Testing echelle gratings: a simple method.

Applied optics·2010
Same author

Blaze characteristics of echelle gratings.

Applied optics·2010
Same author

Multiechelle grating mountings with high spectral resolution and dispersion.

Applied optics·2010
Same journal

Multifunctional reconfigurable terahertz metasurface based on vanadium dioxide phase transition: achieving broadband absorption and efficient polarization conversion.

Applied optics·2026
Same journal

High-Q-factor electromagnetically induced transparency utilizing quasi-bound states in the continuum in an all-dielectric terahertz metasurface.

Applied optics·2026
Same journal

Automated stitching interferometry for high-precision metrology of X-ray mirrors.

Applied optics·2026
Same journal

Experimental demonstration of an approach to designing a metal-dielectric DBR resonant cavity structure.

Applied optics·2026
Same journal

High-precision wavefront reconstruction from a single-shot interferogram using a physics-driven hybrid feature calibration network.

Applied optics·2026
Same journal

Ultra-high-Q Fano resonance based on coupled topological corner states in Kagome photonic crystals.

Applied optics·2026
See all related articles

Related Experiment Video

Updated: Jun 12, 2026

High Resolution Phonon-assisted Quasi-resonance Fluorescence Spectroscopy
10:40

High Resolution Phonon-assisted Quasi-resonance Fluorescence Spectroscopy

Published on: June 28, 2016

Resolving power of multigrating spectrometers.

P Lindblom, F Stenman

    Applied Optics
    |June 18, 2010
    PubMed
    Summary
    This summary is machine-generated.

    The resolving power of spectrometers with multiple gratings is the sum of individual gratings. This study experimentally verifies this finding using the MEGA spectrometer, contradicting prior research.

    More Related Videos

    Coulomb Explosion Imaging as a Tool to Distinguish Between Stereoisomers
    08:51

    Coulomb Explosion Imaging as a Tool to Distinguish Between Stereoisomers

    Published on: August 18, 2017

    Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures
    08:01

    Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures

    Published on: November 21, 2019

    Related Experiment Videos

    Last Updated: Jun 12, 2026

    High Resolution Phonon-assisted Quasi-resonance Fluorescence Spectroscopy
    10:40

    High Resolution Phonon-assisted Quasi-resonance Fluorescence Spectroscopy

    Published on: June 28, 2016

    Coulomb Explosion Imaging as a Tool to Distinguish Between Stereoisomers
    08:51

    Coulomb Explosion Imaging as a Tool to Distinguish Between Stereoisomers

    Published on: August 18, 2017

    Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures
    08:01

    Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures

    Published on: November 21, 2019

    Area of Science:

    • Spectroscopy
    • Optical Engineering
    • Physics

    Background:

    • Resolving power is a critical parameter for spectrometers.
    • Previous studies suggested different models for multi-grating systems.

    Purpose of the Study:

    • To theoretically and experimentally investigate the resolving power of spectrometers utilizing multiple gratings with coacting dispersion.
    • To challenge and provide an alternative to existing models for multi-grating spectrometer resolution.

    Main Methods:

    • Developed a theoretical model for spectrometer resolving power with multiple gratings.
    • Conducted experimental verification using the MEGA spectrometer, equipped with four echelle gratings.
    • Measured the resolving power for a specific laser line (He-Ne 6328 Å).

    Main Results:

    • The theoretical resolving power was found to be the sum of the resolving powers of individual gratings.
    • Experimental measurements confirmed the theoretical prediction.
    • The MEGA spectrometer achieved a measured resolving power of (2.05 ± 0.03) x 10^6 for the He-Ne laser line.

    Conclusions:

    • The resolving power of a multi-grating spectrometer is indeed the sum of the resolving powers of its constituent gratings.
    • This finding contradicts recent research by Mazzacurati et al.
    • The experimental results validate the proposed theoretical model for enhanced spectrometer resolution.