Related Experiment Video
Updated: Jun 12, 2026

05:58
Light-Sheet Imaging to Reveal Cardiac Structure in Rodent Hearts
Published on: March 29, 2024
The Canon speed light transmitter ST-E2
1Doncaster and Bassetlaw Hospitals NHS Foundation Trust, UK. tim.vernon@dbh.nhs.uk
Journal of Visual Communication in Medicine
|June 19, 2010
Summary
No abstract available in PubMed .
More Related Videos
10:30Simultaneously Capturing Real-time Images in Two Emission Channels Using a Dual Camera Emission Splitting System: Applications to Cell Adhesion
Published on: September 4, 2013
10:14Ex Vivo OCT-Based Multimodal Imaging of Human Donor Eyes for Research into Age-Related Macular Degeneration
Published on: May 26, 2023
Related Concept Videos
Electronic Distance Measuring Instruments
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over short distances...
E2 Reaction: Kinetics and Mechanism
SN2 substitutions and E2 eliminations of alkyl halides proceed via a concerted pathway. While the nucleophile attacks the alpha carbon in SN2 reactions, it functions as a strong base and abstracts a beta hydrogen in the E2 mechanism. The rate-limiting transition state in E2 elimination reactions is characterized by partially broken carbon–hydrogen and carbon–halogen bonds and a partially formed pi bond between the alpha and beta carbons. The beta hydrogen and halide are eliminated...
E2 Reaction: Stereochemistry and Regiochemistry
Elimination reactions of alkyl halides can yield one or more alkenes depending on the specific regiochemical and stereochemical considerations. While the regiochemistry of the reaction governs the location of the double bond in the product, the stereochemical requirements often influence the geometry.
When a substrate with two different β hydrogens undergoes an E2 elimination, the presence of a strong base can yield two regioisomeric alkenes. The more-substituted alkene is the major product and...
When a substrate with two different β hydrogens undergoes an E2 elimination, the presence of a strong base can yield two regioisomeric alkenes. The more-substituted alkene is the major product and...
Transmission Electron Microscopy
In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400 keV in...
Fluorescence and Phosphorescence: Instrumentation
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.