A novel subcutaneous counterpulsation device: acute hemodynamic efficacy during pharmacologically induced hypertension, hypotension, and heart failure
Related Experiment Video
Updated: Jun 12, 2026

Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Carlo R Bartoli1, Gregory C Wilson, Guruprasad A Giridharan
1MD/PhD Program, University of Louisville School of Medicine, Louisville, KY, USA.
Abstract:
The miniaturization of mechanical assist devices and less invasive implantation techniques may lead to earlier intervention in patients with heart failure. As such, we evaluated the effectiveness of a novel, minimally invasive, implantable counterpulsation device (CPD) in augmenting cardiac function during impaired hemodynamics. We compared the efficacy of a 32-mL stroke volume CPD with a standard 40-mL intra-aortic balloon pump (IABP) over a range of clinically relevant pathophysiological conditions. Male calves were instrumented via thoracotomy, the CPD was anastomosed to the left carotid artery, and the IABP was positioned in the descending aorta. Hemodynamic conditions of hypertension, hypotension, and heart failure were pharmacologically simulated and data were recorded during CPD and IABP support (off, 1:2, 1:1 modes) for each condition. In all three pathophysiological conditions, the CPD and IABP produced similar and statistically significant (P < 0.05) increases in coronary artery blood flow normalized to the left ventricular (LV) workload. During hypotension and heart failure conditions, however, the CPD produced significantly greater reductions in LV workload and myocardial oxygen consumption as compared with the IABP. A novel 32-mL CPD connected to a peripheral artery produced equivalent or greater hemodynamic benefits than a standard 40-mL IABP during pharmacologically induced hypertension, hypotension, and heart failure conditions.
More Related Videos
Related Concept Videos
Heart Failure Drugs: Inhibitors of Renin-Angiotensin System
Heart Failure V: Medical Management
Heart Failure Drugs: β-Blockers
Antihypertensive Drugs: Vasodilators
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Heart Failure VI: Adjunct Therapies
